New Product Switch Mode Power Supply S8VK-G (15/30/60/120/240/480-W Models) Reliable and Easy Operation-Worldwide Power Supply Resistant in tough environments Easy and fast installation The most compact class on the market • Universal input for worldwide applications: 100 to 240 VAC (85 to 264 VAC) • DC input can be available: 90 to 350 VDC • Possible for 2 phases input usage. • Wide operation temperature range: –40 to 70 °C • Power Boost function at 120% • Safety standards: UL 508/60950-1, CSA C22.2 No.
S8VK-G Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below. S8VK- @@@@@@ 1 2 3 1. Input voltage types G: Single phase 3. Output voltage 05: 5 V 12: 12 V 24: 24 V 48: 48 V 2. Power Ratings 015: 15 W 030: 30 W 060: 60 W 120: 120 W 240: 240 W 480: 480 W Ordering Information Note: For details on normal stock models, contact your nearest OMRON representative.
S8VK-G Specifications Ratings, Characteristics, and Functions Power ratings Item Efficiency (Typical) 230 VAC input Voltage *1 Current (Typical) Power factor (Typical) 30 W 12 V 77% 24 V 80% 5V 79% 12 V 24 V 82% 86% 50/60 Hz (47 to 450 Hz) 115 VAC input 0.32 A 0.3 A 0.31 A 0.5 A 0.57 A 0.58 A 230 VAC input 0.2 A 0.21 A 0.2 A 0.32 A 0.37 A 0.36 A 230 VAC input 0.42 0.43 0.42 0.
S8VK-G Power ratings Item Efficiency (Typical) 230 VAC input Voltage *1 Current (Typical) Power factor (Typical) 85% 120 W 24 V 88% 50/60 Hz (47 to 450 Hz) 24 V 89% 50/60 Hz (47 to 63 Hz) 115 VAC input 1.0 A 1.1 A 230 VAC input 0.6 A 0.7 A 230 VAC input 0.46 0.45 Harmonic current emissions Output 12 V 100 to 240 VAC, 90 to 350 VDC (allowable range: 85 to 264 VAC) Frequency *1 Input 60 W Output voltage 1.3 A 0.
S8VK-G Power ratings Item Efficiency (Typical) 230 VAC input Voltage *1 Current (Typical) Power factor (Typical) 480 W 48 V 92% 24 V 48 V 93% 50/60 Hz (47 to 63 Hz) 115 VAC input 2.4 A 4.7 A 230 VAC input 1.3 A 2.3 A 230 VAC input 0.9 (with PFC) 0.97 (with PFC) Harmonic current emissions Output 24 V 100 to 240 VAC, 90 to 350 VDC (allowable range: 85 to 264 VAC) Frequency *1 Input 240 W Output voltage Conforms to EN61000-3-2 Leakage current (Typical) 115 VAC input 0.23 mA 0.
S8VK-G Connections Block Diagrams S8VK-G015@@ (15 W) AC (L) INPUT +V Fuse: 250 VAC 3.15 A HBC +V Noise filter −V AC (N) Rectifier Inrush Smoothing current circuit protection Rectifier/ smoothing circuit DC OUTPUT −V Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Photocoupler S8VK-G030@@ (30 W) AC (L) INPUT +V Fuse: 250 VAC 4.
S8VK-G S8VK-G12024 (120 W) +V Fuse: 250 VAC 5.0 A HBC AC (L) INPUT +V −V DC OUTPUT Noise filter AC (N) Rectifier Harmonic current Inrush current Smoothing suppression circuit protection circuit (Power factor improvement) circuit Rectifier/smoothing circuit −V −V Drive control circuit Voltage detection circuit Overcurrent detection circuit Overvoltage detection circuit Photocoupler S8VK-G240@@ (240 W) +V Fuse: 250 VAC 8.
S8VK-G Construction and Nomenclature Nomenclature 15-W Models 30-W Models 60-W Models S8VK-G015@@ S8VK-G030@@ S8VK-G060@@ 1 3 3 3 4 4 4 5 5 5 1 2 2 1 120-W Models 240-W Models 480-W Models S8VK-G12024 S8VK-G240@@ S8VK-G480@@ 3 3 1 No. 1 2 3 4 5 2 4 4 4 5 5 5 2 Name Input terminals (L), (N) Protective Earth terminal (PE) DC Output terminals (V), (+V) Output indicator (DC ON: Green) Output voltage adjuster (V.
S8VK-G Engineering Data 15, 30, 240 W (S8VK-G015@@, S8VK-G030@@, S8VK-G240@@) 120 W (S8VK-G12024) Load ratio (%) Load ratio (%) Derating Curve 120 100 A 80 120 100 A 80 B B 60 60 40 40 20 20 0 −40 −25 0 −40 −10 0 10 20 30 40 50 60 70 80 −25 −10 0 10 20 30 40 50 60 70 80 Ambient temperature (°C) Ambient temperature (°C) Note: 1. At less than 90 VAC, the derating is 2.5%/V 2.
S8VK-G Mounting Power Boost Function (A) Standard (Vertical) mounting (B) Face-up mounting For All Models Power Boost is a function that can output the temporary repeated boost current larger than the rated current. However, it should meet the following four Boost current conditions. 1. Time that the boost current flows: t1 2. The maximum value of the boost current: lp 3. The average output current: lave 4.
S8VK-G Overvoltage Protection L1 L2 L3 PE Output voltage (V) Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails. If an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage is shut OFF. Reset the input power by turning it OFF for at least three minutes and then turning it back ON again. +30% (approx.
S8VK-G Dimensions (Unit: mm) S8VK-G015@@ (15 W) (1) 5 3.6 dia. (Bit #1) 90 86 90 75.4 3.6 dia. (Bit #1) Rail Stopper 34.7 3.5 4.7 (Sliding: 10 max.) 5.08 22.5 S8VK-G030@@ (30 W) (1) 5 3.6 dia. (Bit #1) 90 86 90 75.4 3.6 dia. (Bit #1) Rail Stopper 34.7 3.5 4.7 (Sliding: 10 max.) 7.62 32 S8VK-G060@@ (60 W) (1) 5 3.6 dia. (Bit #1) 12 34.9 90 75.4 3.6 dia. (Bit #1) Rail Stopper 110 106 7.62 32 4.7 (Sliding: 10 max.) 3.
S8VK-G S8VK-G12024 (120 W) 122.2 117.8 112.2 (1) 5.0 dia. (Bit #2) 6.35 104.6 (4) 34.7 125 5.0 dia. (Bit #2) Rail Stopper 4.7 (Sliding: 7.5 max.) 6.35 40 (10) S8VK-G240@@ (240 W) 6.35 5.0 dia. (Bit #2) 150 145.6 140 (1) (4) 125 104.6 34.7 5.0 dia. (Bit #2) Rail Stopper (10) 6.35 4.7 (Sliding: 7.5 max.) 60 S8VK-G480@@ (480 W) (1) 150 145.6 140 (4) 125 34.7 52.3 5.0 dia. (Bit #2) 6.35 6.35 95 Rail Stopper 5.0 dia. (Bit #2) 4.7 (Sliding: 7.5 max.
S8VK-G DIN Rail (Order Separately) Note: All units are in millimeters unless otherwise indicated. Mounting Rail (Material: Aluminum) PFP-100N PFP-50N 7.3±0.15 4.5 35±0.3 15 25 10 25 25 10 1,000 (500) * 25 27±0.15 15(5) * 1 * Values in parentheses are for the PFP-50N. Mounting Rail (Material: Aluminum) PFP-100N2 16 4.5 35±0.3 27 15 25 10 25 25 10 1,000 25 15 24 29.2 1 1.5 End Plate PFP-M 10 6.2 M4×8 panhead screw 1.8 1 50 1.8 35.5 35.5 11.5 10 M4 spring washer 1.3 4.
S8VK-G Mounting Brackets Name Model Front-mounting bracket (for 15, 30 and 60 W models) S82Y-VS10F Front-mounting bracket (for 120, 240 and 480 W models) S82Y-VK10F Side-mounting bracket (for 15 W models) S82Y-VK15P Side-mounting bracket (for 30 and 60 W models) S82Y-VS10S Side-mounting bracket (for 120 W models) S82Y-VK10S Side-mounting bracket (for 240 W models) S82Y-VK20S Type Model Dimensions Appearance 41 35 25 4.5 dia.±0.
S8VK-G Type Model Dimensions Appearance 4.5 dia.±0.1 Side-mounting bracket (For 30 and 60 W models) Left-side mounting Right-side mounting Left-side mounting Right-side mounting Left-side mounting Right-side mounting 60±0.1 80 S82Y-VS10S 55±0.1 35 13 64 t = 2.0 73 40 49 50±0.1 15.5±0.1 4.5 dia.±0.1 Side-mounting bracket (For 120 W models) S82Y-VK10S 140±0.1 125 150 t = 2.0 73 40 59 50±0.1 15.5±0.1 4.5 dia.±0.1 Side-mounting bracket (For 240 W models) 140±0.
S8VK-G Safety Precautions Warning Indications CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance.
S8VK-G Precautions for Safe Use Wiring Connect the ground completely. A protective earthing terminal stipulated in safety standards is used. Electric shock or malfunction may occur if the ground is not connected completely. Minor fire may possibly occur. Ensure that input and output terminals are wired correctly. Do not apply more than 75-N force to the terminal block when tightening it.
S8VK-G Precautions for Correct Use Mounting DIN Rail Mounting Take adequate measures to ensure proper heat dissipation to increase the long-term reliability of the Product. Be sure to allow convection in the atmosphere around devices when mounting. Do not use in locations where the ambient temperature exceeds the range of the derating curve. When cutting out holes for mounting, make sure that cuttings do not enter the interior of the Products.
S8VK-G Therefore, connect bypass diodes (D1, D2) as shown in the following figure. If the list of models that support series connection of outputs says that an external diode is not required, an external diode is also not required for positive/negative outputs. D1 +V INPUT D2 Load Load −V Load +V INPUT −V Use the following information as a guide to the diode type, dialectic strength, and current.
Read and Understand this Catalog Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No.