Safety Precautions
Warning Indications
Do not wire anything to the release holes.
Do not tilt or twist a flat-blade screwdriver while it is inserted into a
release hole on the terminal block. The terminal block may be
damaged.
Insert a flat-blade screwdriver into the release holes at an angle.
The terminal block may be damaged if you insert the screwdriver
straight in.
Do not allow the flat-blade screwdriver to fall out while it is inserted
into a release hole.
Do not bend a wire past its natural bending radius or pull on it with
excessive force.
Doing so may cause the wire disconnection.
Do not insert more than one wire into each terminal insertion hole.
Do not install the Terminal Block upside down when mounting
multiple Terminal Blocks.
Doing so may cause short circuits with the adjacent Terminal
Block.
To prevent wiring materials from smoking or ignition, use the wiring
materials given in the following table.
Note: Please use Ferrules with UL certification (R/C).
1. Precautions for Correct Use
Do not drop the Terminal Block.
Terminal Block functionality may be inhibited.
Always attach End Cover. Not doing so may cause electrical
shock.
When you wire the Terminal Block, do not subject it or the wires to
stress. Secure the wires so that they do not resonate with
vibrations from the facilities in installation conditions.
Always turn OFF the power supply before wiring. Electrical shock
may occur.
2. Connecting Wires to the Push-In Plus Terminal
Block
Part Names of the Terminal Block
Connecting Wires with Ferrules and Solid Wires
Insert the solid wire or ferrule straight into the terminal block until the
end strikes the terminal block.
If a wire is difficult to connect because it is too thin, use a flat-blade
screwdriver in the same way as when connecting stranded wire.
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal block.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole. The angle should be between 10° and 15°.
If the flat-blade screwdriver is inserted correctly, you will feel the
spring in the release hole respond.
2. With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until it strikes the terminal
block.
3. Remove the flat-blade screwdriver from the release hole.
Precautions
for Safe Use
Supplementary comments on what to do or
avoid doing, to use the product safely.
Precautions
for Correct
Use
Supplementary comments on what to do or
avoid doing, to prevent failure to operate,
malfunction, or undesirable effects on
product performance.
Precautions for Safe Use
Stripping length
Recommended
Wire
With Ferrules
Without Ferrules
XW5T-P1.5-@-@@
0.08 to 1.5 mm
2
/
AWG 28 to 14
8 mm 8 mm
XW5T-P2.5-@-@@
0.25 to 4 mm
2
/
AWG 24 to 12
10 mm 10 mm
XW5T-P4.0-@-@@
0.25 to 6 mm
2
/
AWG 24 to 10
12 mm 12 mm
Precautions for Correct Use
Release hole
Terminal (Insertion) hole
Ferrule or solid wire
Terminal (Insertion) hole
10 to 15°
1
3
2
Flat-blade screwdriver
Wire