User's Manual
Table Of Contents
- Read and Understand this Manual
- Warranty
- Limitations of Liability
- Suitability for Use
- Programmable Products
- Change in Specifications
- Dimensions and Weights
- Errors and Omissions
- Applicable Standards
- Applicable SEMI Standards
- Precautions for Safe Use
- Precautions for Correct Use
- Editor’s Note
- Table of Contents
- What is a CIDRW System?
- Features
- System Configuration
- Component Names and Functions
- Flowchart for Getting Started
- Installation
- Connections and Wiring
- Set the Communications Conditions for the CIDRW Controller
- Set the Communications Conditions for Amplifier Units
- Set the Communications Conditions for Link Units
- Communications Test
- When SECS is Used
- When SECS is Not Used
- When SECS is Used
- When SECS is Not Used
- Specifications and Dimensions
- Data Segment Area
- Regular Inspection
- SECS Protocol Specifications
- ASCII Code Table
- Protective Construction
68
SECTION 3
Communications Test
CIDRW System
User’s Manual
SECTION 3
Preparing for Communications
When SECS is Not Used
•Read
Reading the page 1 and page 3 data of node No.1:
•Write
Writing data to page 8 and page 10 of node No.1:
The ID Tag status on normal completion is as shown below:
Data content of the ID Tag
Page 1 12h 34h 56h 78h 90h 12h 34h 56h
Page 2
Page 3 11h 22h 33h 44h 55h 66h 77h 88h
Page 4
SOH Node No.
Response
code
Page 1 Page 3 FCS CR
01h 0 1 0 0 12345678901234561122334455667788070Dh
SOH Node No.
Response
code
FCS CR
01h0100010Dh
Page 8 11h 22h 33h 44h 55h 66h 77h 88h
Page 9
Page 10 01h 23h 45h 67h 89h ABh CDh EFh
Command
00000000000000000000000000010100
Binary notation
SOH Node No. Command code Page designation FCS CR
01h01010000000014050Dh
Response
Command
00000000000000000000101000000000
SOH
Node
No.
Command
code
Page designation Data of page 8 Data of page 10 FCS CR
01h 0 1 0 2 0 000000A0011223344556677880123456789ABCDEF 7 4 0Dh
Binary notation
Response