User's Manual

Table Of Contents
7-5 Functions
7-18
7-5-9 Statistic Error Information
The controller adds the number of error occurrences per error at every error occurrence. At the same time, the controller calculates
MCBF. Those data are all stored in memory. However, when the power supply turns off or the system is reset, all the stored data are
erased.
Error Indication List
Error Code Error Name Error Code Error Name
10 PARITY E 70 COM.DC E
11 FRAMING E 71 VERIFY E
12 OVERRUN E 72 NO DC E
13 FCS_E 7A ADRS E
14 FORMAT E 7B WT AREA E
15 RUN E 7C ANT E
18 FRAME E 7D PROTECT E
7E ID SYS1 E
9A E2PROM_E 7F ID SYS2 E
Correct Usage
If you want to keep the statistic error information, neither turn off the power supply nor reset the system.
Those are read out per error code in ascending
numeric order of error code number. The error
information is changed and displayed with the
/
key(s).
MCBF = Total number of host commands / num-
ber of total error occurrences
When the details of all the error occurrences
have been displayed, MCBF is displayed by
pressing the key.
As shown in this screen, the details of the statis-
tic error information are the number of error
occurrences, error code and error name. A
maximum number of error occurrences is 999.
No error is added any more.
Error Name
Error Code
Number of Error
Occurrences
Total number of commands
Communication error/ Number of total system error occurrences
MCBF =