User's Manual

Table Of Contents
2-1 Controller
2-2
No.
Name Function Description
(1) Note number setup switch Sets a controller node
number.
Used to identify the controllers when a maximum of 31
controllers are connected to one host computer.
(2) Dip switch Sets every mode. Sets an input function, operation mode, protocol, com-
munication conditions, etc.
(3) LED display An operation status is shown on this LED displayed.
RUN Green Shows the RUN sta-
tus.
Turns on when an operation is normal.
COMM Green Shows an operation
status.
Turns on during the communication to a tag.
NORM/ERR Green Shows the end of
communication.
Turns on once and turns off when the communication has
ended correctly.
Red Shows an error. Turns on once and turns off when the communication has
ended due to an error. Turns on when a system error
occurs.
RST/IN Green
Shows an input status.
Turns on when the RST/IN input signal turns ON.
OUT1 Green
Shows an output status.
Turns on when the OUT1 output signal turns ON.
OUT2 Green
Shows an output status.
Turns on when the OUT2 output signal turns ON.
(4) Cover
Cover common to (1), (2) and (5).
Open as necessary.
(5) Connecting port for pro-
gramming console
Used to connect a
programming con-
sole.
Our programming console type C200H-PRO27 (unbun-
dled) can connect to this port through the connecting
cable model V700-P10 (unbundled). When you operate
the programming console, use the key sheet that comes
with the V700-P10.
(6) Connecting port for antenna Used to connect an
antenna.
One antenna can connect to this port. To extend the
cable, use model V670-A4
(unbundled).
(7) RS-232C port Used to connect a
host device.
Based on the RS-232C, a general-purpose programma-
ble controller (PLC) and PC can connect to this port.
(8) Power supply terminal Terminal for power supply.
24 VDC+ Supplies the power. Connects the "+" side of 24 VDC power supply.
24 VDC- Connects 0 V.
GR Ground Class D (Class III).
(9) Input terminal Terminal for input.
RST/IN Supplies a reset sig-
nal or trigger signal.
When external reset input and external trigger input are
used, they connects to this terminal together with 24
VDC- in pairs. Function can be selected with a dip
switch.
(10)
Output terminal Terminal for output.
OUT1 Output signal 1 When external output is used, it connects to this terminal
together with O.COM in pairs.
OUT2 Output signal 2
O.COM Output common