User's Manual

Table Of Contents
5-8 Controller Control Command
5-19
5-8-3 Reset (XZ)
Aborts all the controller processes and performs "Power ON" initial process. There is no response.
<Response>
Nil
5-8-4 Controller Control (CC)
Changes or obtains the state of external I/O of controller.
Process code Fixed to "00" (I/O control).
External output informa-
tion
Specifies the output of external output 1 and external output 2.
"0": No change
"1": Turned OFF forcibly.
"2": Turned ON forcibly.
External input informa-
tion
Returns the signal status when a command of external input has been received. (The sec-
ond character is always "0".)
"0": "OFF"
"1": "ON"
External output informa-
tion
Returns the signal status when a command of external output 1 and external output 2 has
been received.
"0": "OFF"
"1": "ON"
<Command>
Command
code
"XZ"
<Command>
Command
code
"CC"
Process code
External out-
put information
<Response>
Command
code
"CC"
Termination
code
Retrans-
mission
flag
Status
flag
External input
information
External output
information