User manual
15
EN
9. Technical Data
Note: Subject to technical modification without prior notice.
This device fulfills the provisions of the EC directive 93/42/EEC (Medical Device Directive).
Product Category Body Composition Analyzers
Product Description Body Composition Monitor
Model (Code) BF511 (HBF-511T-E/HBF-511B-E)
Display
Body Weight:
0 to 150 kg with an increment of 0.1 kg
(0.0 to 330.0 lb with an increment of 0.2 lb)
Body Fat percentage:
5.0 to 60.0% with an increment of 0.1%
Skeletal Muscle percentage:
5.0 to 50.0% with an increment of 0.1%
BMI:
7.0 to 90.0 with an increment of 0.1
Resting Metabolism:
385 to 3999 kcal with an increment of 1 kcal
Visceral Fat Level:
30 levels with an increment of 1 level
BMI classification:
– (Underweight) / 0 (Normal) / + (Overweight) / ++ (Obese) 4 levels with 3 sublevels each
Body fat percentage and Skeletal muscle percentage classification:
– (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels with 3 sublevels each
Visceral fat level classification:
0 (Normal) / + (High) / ++ (Very High) 3 levels with 3 sublevels each
Setting Items Height: 100.0 to 199.5 cm (3' 4" to 6' 6 3/4")
Age: 6 to 80 years old
Gender: Male/Female
* Measurement Units: kg (cm) / lb (feet•inch)
* The age range for the Body Fat percentage, Body Fat percentage classification,
Skeletal Muscle percentage, BMI and BMI classification and Resting
Metabolism rate is 6 to 80 years old.
* The age range for Visceral Fat level, Visceral Fat level classification and
Skeletal Muscle percentage classification is 18 to 80 years old.
Weight Accuracy
0.0 kg to 40.0 kg:
±
0.4 kg
(0.0 lb to 88.2 lb:
±
0.88 lb)
40.0 kg to 150.0 kg:
±
1%
(88.2 lb to 330.0 lb:
±
1%)
Accuracy (S.E.E.)
Body Fat percentage:
3.5%
Skeletal Muscle percentage:
3.5%
Visceral Fat Level:
3 levels
Durable Period
5 years
Power Supply
4 AA batteries (R6) (You may also use AA alkaline batteries (LR6).)
Battery Life
Approximately 1 year (when manganese batteries are used with four measurements
a day)
Operating Temperature /
Humidity / Air Pressure
+10 to 40°C / 30 to 85% RH (non-condensing) / 700 to 1060 hPa
Storage and Transport
Temperature / Humidity /
Air Pressure
-20 to 60°C / 10 to 95% RH (non-condensing) / 700 to 1060 hPa
Protection Against
Electric Shock
Internally powered ME equipment
Applied Part
Type BF (Grip Electrodes, Foot Electrodes)
IP Classification
IP21
*IP classification is degrees of protection provided by IEC 60529.
This unit is protected against solid foreign objects of diameter 12.5mm such as a finger and greater. This unit is
protected against the ingress of vertically falling water drips.
Weight
Approximately 2.2 kg (4.85 lb) (including batteries)
External Dimensions
Display unit:
Approx. 300 (W) × 35 (H) × 147 mm (D)
(Approx. 11 3/4" (W) x 1 3/8" (H) x 5 3/4" (D))
Main unit:
Approx. 303 (W) × 55 (H) × 327 mm (D)
(Approx. 11 7/8" (W) x 2 1/8" (H) x 12 7/8" (D))
Package Contents
Body Composition Monitor, 4 AA manganese batteries (R6), instruction manual,
Guarantee Card