System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations Appendix C
A620 to
A621
00 to 15 Pulse Output 1 PV
Note This item applies when the
operation mode is relative pulse
output, absolute pulse output in
linear mode, absolute pulse out-
put in circular mode, or elec-
tronic cam mode.
Contains the pulse output PV as an 8-digit hexadecimal number.
Relative mode: 00000000 to FFFFFFFF hex
Absolute linear mode: 80000000 to 7FFFFFFF hex
Absolute circular mode: 00000000 to circular maximum count
Module
One-shot Pulse Output 1 ON
Time
Note This item applies when the
operation mode is one-shot out-
put mode.
Contains the time that the one-shot pulse output has been ON as
an 8-digit hexadecimal number.
0000 0000 to 0000 270F (unit: set by STIM(980))
Pulse Time Measurement 1
Note This item applies when the
operation mode is time measure-
ment mode using a pulse
counter.
Contains the time measured by the pulse counter as an 8-digit
hexadecimal number.
0000 0000 to FFFF FFFF hex (unit: set by STIM(980))
A622 to
A623
00 to 15 Pulse Output 2 PV Same as for Pulse Output 1 PV.
One-shot Pulse Output 2 ON
Time
Same as for One-shot Pulse Output 1 ON time.
Pulse Time Measurement 2 Same as for Pulse Time Measurement 1.
A624 00 Pulse Output 1
Status
Pulse Output
Completed
Flag
OFF: Pulse output not completed (OFF during pulse output).
ON: Pulse output completed (ON when pulse distribution has been
completed).
01 Pulse Output
Set Flag
OFF: Pulse output amount not set by PULS(886).
ON: Pulse output amount set by PULS(886).
02 Target Fre-
quency Not
Reached Flag
OFF: Target speed has been reached during pulse output for
PLS2(887).
ON: Decelerated before reaching the target speed during pulse
output for PLS2(887).
03 Target Compar-
ison Flag
OFF: Comparison stopped.
ON: Comparison in progress.
04 Independent
Pulse Output
Flag
OFF: Pulses not being output or being output continuously.
ON: Pulses being output.
05 PLS2 Position-
ing Flag
OFF: Not positioning.
ON: Positioning in progress.
06 Accelerating/
Decelerating
Flag
OFF: No output or constant-speed output.
ON: Acceleration or deceleration in progress for ACC(888) or
PLS2(887).
07 Pulse Output
Flag
OFF: Pulse output stopped.
ON: Pulse output in progress.
08 to 15 Reserved ---
A625 00 Pulse Output 2
Status
Pulse Output
Completed
Flag
Same as for Pulse Output 1 Status.
01 Pulse Output
Set Flag
02 Target Fre-
quency Not
Reached Flag
03 Target Compar-
ison Flag
04 Independent
Pulse Output
Flag
05 PLS2 Position-
ing Flag
06 Accelerating/
Decelerating
Flag
07 Pulse Output
Flag
08 to 15 Reserved
Address Bits Name Function Controlled
by