Datasheet

4
G2R PCB Power Relay
G
2
R
Ratings
Coil
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of+15%/-20% (AC rated current) or ±10% (DC coil resistance).
2.AC coil resistances shown above are only reference values.
3.The operating characteristics are measured at a coil temperature of 23°C.
4.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Coil: Double-winding Latching Relays
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Classification
Item Rated current (mA)
Coil resistance
(Ω)
Must operate
voltage (V)
Must release
voltage (V)
Max. voltage
(V)
Power
consumption
(VA, W)
Rated voltage 50 Hz 60 Hz % of rated voltage
General-purpose
Quick-connect
Fully sealed
High-capacity
12 VAC 93 75 65
80% max. 30% min.
140%
(at 23°C)
Approx. 0.9
(60 Hz)
24 VAC 46.5 37.5 260
100/(110) VAC 11 9/(10.6) 4,600
200/(220) VAC 5.5 4.5/(5.3) 20,200
General-purpose
High-capacity
Bifurcated contact
Quick-connect
Fully sealed
5 VDC 106 47
70% max. 15% min.
170%
(at 23°C)
Approx. 0.53
6 VDC 88.2 68
12 VDC 43.6 275
24 VDC 21.8 1,100
48 VDC 11.5 4,170
100 VDC 5.3 18,860
High-sensitivity
5 VDC 71.4 70
70% max. 15% min.
170%
(at 23°C)
Approx. 0.36
6 VDC 60 100
12 VDC 30 400
24 VDC 15 1,600
48 VDC 7.5 6,400
Item Set Coil Reset coil
Must set
voltage (V)
Must reset
voltage (V)
Max. voltage
(V)
Power consumption
Rated voltage
Rated current
(mA)
Coil resistance
(Ω)
Rated current
(mA)
Coil resistance
(Ω)
% of rated voltage
Set Coil
(mW)
Reset coil
(mW)
5 VDC 167 30 119 42
70% max. 70% max.
140%
(at 23°C)
Approx.
850
Approx.
600
6 VDC 138 43.5 100 60
12 VDC 70.6 170 50 240
24 VDC 34.6 694 25 960