Instruction Manual Ultra Compact Wrist Blood Pressure Monitor with Model HEM-630 S Y S m m Hg in m E/ LS PU D m m Hg N O F F O IA M E IM /T TE DA T SE Thank you for purchasing the Omron Ultra Compact Wrist Blood Pressure Monitor with IntelliSense™. Please read this instruction manual thoroughly before operating to assure proper use. For specific information on your own blood pressure, CONTACT YOUR PHYSICIAN.
Contents Introduction ……………………………………………………………………… 2 Know Your Unit ………………………………………………………………… 3 Battery Installation/Replacement ……………………………………………… 4 Program Date and Time ……………………………………………………… 5, 6 Suggestions for Measuring Blood Pressure …………………………………… 7 How to Apply the Wrist Cuff ………………………………………………… 8,9 How to Take a Reading …………………………………………………… 10,11 Memory Feature …………………………………………………………… 12,13 Troubleshooting …………………………………………………………… 14,15 Care and Maintenance ………………………………………………………… 16 Caution ………
Introduction Thank you for purchasing the Omron HEM-630 Ultra Compact Wrist Blood Pressure Monitor. This remarkable instrument is ideal for people who frequently monitor their own blood pressure because it’s so compact and easy to use. There is no tricky arm cuff, just a small, pre-formed wrist cuff that is easy to apply. With the push of a button the Omron Wrist Monitor measures your blood pressure and pulse and displays the reading on a clear digital panel.
Know Your Unit Main unit Systolic Blood Pressure Display Diastolic Blood Pressure / Pulse Display S Y S Hg m m in m E/ LS PU D m m Hg N O F F O IA M START/STOP Button E IM /T TE DA Wrist Cuff T SE Memory Call Button Time Setting Button Battery Cover Accessories Two AAA Alkaline batteries (LR03) Storage case INTELLISENSE™ Blood Pressure Monitor is a global brand name of blood pressure monitor equipped with bio-information sensing and high performance fuzzy logic technology, which are the ke
Battery Installation/Replacement Insert the batteries. (1) Slide the Battery Cover in the direction of an arrow. 1 (2) Open the Battery Cover. (3) Insert two AAA batteries with the polarities in correct direction. (4) Pull the Battery Cover toward yourself. 2 3 (5) Slide the Battery Cover to close. * Battery Cover slides to open and close. Please be careful that if you force to open or close the Battery Cover, it may be damaged.
Program Date and Time Set the year, month, date, and time. Time Setting Button SYS mm D IA mm Hg SET E/m in M Hg PULS DAT E/T IME Press the Time Setting button with something having a sharp point (such as ball-point pen) while the power is off. • "0:00" or the current time (when the time is already set) is displayed. (If you insert batteries for the first time after purchasing this monitor, the display will flash.) 1. Set the "Year". Press the Time Setting button again.
Program Date and Time 3. Set the "Date". Press the Time Setting button. • " / 1" (date) is displayed. • Press the Memory Call button and set the number representing the "Date". 4. In the same manner, set the "Hour" and "Minute". • The number representing the "Hour" is displayed in the 12-hour unit of morning and afternoon. (For the hour in the afternoon, PM is displayed.) 5. Lastly, the correct time can be set by pressing the Time Setting button according to the time signal when "00" is displayed.
How to Apply the Wrist Cuff Wrap the Wrist Cuff. 1. Place the wrist cuff over your left wrist with your left thumb facing upward. * Wrap the wrist cuff over bare skin. * Be sure not to roll in the sleeve of your cloth into the wrist cuff. * As shown in the Figure, cover the wrist cuff by leaving a space of 10 to 15 mm 10 - 15 mm (a space almost equal to the width of an index finger) between the edge of the wrist cuff and the border of arm and the palm of a hand. 2.
Suggestions Before Measureing Blood Pressure Align the wrist cuff with the level of your heart (breast height) and gently support your left hand with your right hand. 1. 2. Avoid eating, smoking and exercising for at least 30 minutes before taking measurement. Also rest for at least 10 to 15 minutes before taking a reading. Stress raises blood pressure. Avoid taking measurements during stressful times. 3. The cuff should be applied to your left wrist. 4.
How to Take a Reading When it is ready to measure, take the measurement in the following procedure. To start measurement, simply press the START/STOP button. 1. Press the START/STOP button. (1) Press the START/STOP button. Release the Button when the display turns on. SYSmmHg PULSE/min DIA mmHg (2) Initial display All display symbols turn on for about 0.5 seconds. * The battery replacement mark shown here does not mean the worn batteries. (3) Deflation display A mark starts to flash.
How to Take a Reading 2. Measurement is over and blood pressure values, pulse, time, and date are displayed. When the measurement is over, a mark flashes, and the cuff deflates automatically. Then a mark turns on and blood pressure and time are displayed alternately, and pulse rate and date are displayed alternately.
Memory Feature How to Use the Memory Function The HEM-630 Blood Pressure Monitor with Fuzzy Control has a function to record up to twenty-one measurements. 1. Press the MEMORY CALL button ("M" button). Alternating display DIA mmHg PULSE/min DIA mmHg Alternating display SYSmmHg PULSE/min DATE/TIM DATE/TIM E SET SYSmmHg M Each time the "M" button is pressed, the measured values are called from the latest ones. Press the "M" button.
Memory Feature 2. Press the START/STOP button to turn off the power. After reading the blood pressure values and pulse rate stored in the monitor, press the START/STOP button to turn off the power. SYSmmHg PULSE/min DIA mmHg * Even if you forget to turn off the power, the monitor will turn off automatically in approximately 2 minutes. * The stored measurements will remain in the memory even when The batteries are removed for battery replacement.
Troubleshooting Symptom Cause What to do No display appears when the START/STOP button is pressed. Batteries are dead. Replace with new batteries Batteries were inserted incorrectly. Put the batteries in with the right (+) (-) orientation. Are you holding the wrist cuff at heart? Measure with the correct posture. Is the cuff wrapped snugly around the wrist? Wrap the wrist cuff correctly. Are your arms and shoulders tense? Relax and then measure.
Troubleshooting When measurement is not being performed as normal, the following error messages may appear to indicate what is necessary for correct measurement. Error Display Causes After several seconds Movement of arm or body or talking during measurement. What to do Press the START/STOP button once turn off power. Sit still and restart measurement. After several seconds Vigorous movement of arm or body during measurement. The batteries are dead. 15 Replace with new batteries.
FCC Caution Caution Changes or modifications not expressly approved by Omron Healthcare, Inc. could void the user’s authority ot operate this product. Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Care and Maintenance To protect your monitor from damage, please AVOID the following: Subjecting your monitor to extreme temperatures, humidity, and direct sunlight Washing or moistening the cuff Disassembling the monitor Subjecting the monitor to strong shocks (for example, dropping the monitor on the floor) Cleaning the monitor with volatile liquids. THE MONITOR SHOULD BE CLEANED WITH A SOFT, DRY CLOTH.
Limited Five Year Warranty Your Omron HEM-630 Ultra Compact Wrist Blood Pressure Monitor with Intellisense™ is warranted to be free from manufacturing defects for a period of five years under normal use. The five year warranty excludes the monitor cuff. The cuff is warranted for a one year period. This warranty extends only to the original retail purchaser. Should repair be needed within the warranty period, ship the unit prepaid to Omron Healthcare, Inc.
Specifications Name: Model: Display: Measurement: Measurement Range: Accuracy: Inflation: Deflation: Pressure Detection: Power Supply: Battery Life: Operating Temperature and Humidity: Storage Temperature and Humidity: Measurable Circumference of Wrist: Weight of Main Unit External Dimensions: Electric Shock Protection: Accessories: OMRON Automatic Blood Pressure Monitor HEM-630 Digital display Oscillometric method Pressure; 0 to 280 mmHg Pulse rate; 40 to 200 beats/min Pressure; Within ±4 mmHg Pulse rate
Manufactured For: Omron Healthcare, Inc. 300 Lakeview Parkway Vernon Hills, IL 60061 Copyright © 7/2001 Omron Healthcare, Inc. www.omronhealthcare.