BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 2 Before Using the Monitor CONTENTS Before Using the Monitor Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Risk of Electrical Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Care and Maintenance . . . . .
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 3 INTRODUCTION Thank you for purchasing Omron® BP755 IntelliSense® Automatic Blood Pressure Monitor with the ComFit™ Cuff. Fill in for future reference. DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ Staple your purchase receipt here Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 4 SAFETY INFORMATION To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 5 SAFETY INFORMATION OPERATING THE DEVICE (continued) This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. Read the Special Conditions section (page 24) of the instruction manual if your systolic pressure is known to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 6 SAFETY INFORMATION CARE AND MAINTENANCE Do not subject the monitor to strong shocks, such as dropping the unit on the floor. Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes or modification not approved by the manufacturer will void the user warranty. Do not disassemble or attempt to repair the unit or components.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 7 BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. Avoid taking measurements during stressful times. 3. Measurements should be taken in a quiet place. 4. Remove tight-fitting clothing from your left arm. 5.
BP755IM_E_SP_q6_R2.
BP755IM_E_SP_q6_R2.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 10 DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that is more than 25% slower or 25% faster from the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 11 DISPLAY SYMBOLS HEARTBEAT SYMBOL/HYPERTENSION INDICATOR ( ) TAKING A MEASUREMENT The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat. When the measurement is complete, the Heartbeat Symbol ( ) flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and/or above 85 for the Diastolic Blood Pressure value.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 12 DISPLAY SYMBOLS The American Heart Association recommends the following guideline for upper limit of normal for home blood pressure readings: AHA Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on age and morbidity.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 13 USING THE AC ADAPTER IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS - DANGER TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, CAREFULLY FOLLOW THESE INSTRUCTIONS. For connection to a power supply not in the U.S.A., use an attachment plug adapter of the proper configuration for the power outlet. The power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor mount position.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 14 USING THE AC ADAPTER To connect the AC Adapter ① Insert the AC Adapter Plug into the AC Adapter Jack on the back side of the monitor as illustrated. ② Plug the AC Adapter into a 120V AC outlet (60 cycles). Housing Cord To disconnect the AC Adapter ① Hold and pull the housing to remove the AC Adapter from the electrical outlet. Do not remove by pulling the cord. ② Remove the AC Adapter plug from the monitor.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 15 BATTERY INSTALLATION NOTE: Use 4 new “AA” size batteries - long life alkaline batteries are recommended. 1. Press the ▼ indicator on the battery cover and slide the cover off in the direction of the arrow. 2. Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated. NOTE: 4 “AA” size batteries are not included in this unit. 3. Replace the battery cover.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 16 BATTERY INSTALLATION BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display screen, turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. Long-life alkaline batteries are recommended. WARNING If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately. NOTES: • Turn the unit off before replacing the batteries.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 17 SETTING THE DATE AND TIME Set the monitor to the current date and time before taking a measurement for the first time. If the current date and time are not set correctly, the measurement values stored in the memory and the average values may not be correct. 1. TO START THE SETTING Press the Date/Time Setting button ( ) to adjust the date and time. The year flashes on the display. ® 2. SETTING THE YEAR The year can be set between 2006 and 2030.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 18 SETTING THE DATE AND TIME 3. SETTING THE MONTH Press the Memory Up button of one month. to advance by increments Press the Date/Time Setting button ( the current month. ) to set ® The day flashes on the display. 4. SETTING THE DAY Press the Memory Up button by increments of one day. to advance Press the Date/Time Setting button ( the current day. ) to set ® The hour flashes on the display. 5. SETTING THE HOUR The time is set using AM or PM.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 19 SETTING THE DATE AND TIME 6. SETTING THE MINUTE Press the Memory Up button of one minute. to advance by increments Press the Date/Time Setting button ( ) to set the current minute. The year flashes on the display. 7. TO TURN THE MONITOR OFF Press the START/STOP button. NOTE: The monitor will automatically turn off after the minute has been set after battery replacement.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 20 APPLYING THE ARM CUFF CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. APPLYING THE CUFF ON THE LEFT ARM 1. Make sure the air plug is securely inserted in the main unit. T STAR STOP MEM 2.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 21 APPLYING THE ARM CUFF 3. Hold the thumb grip on the cuff securely with your hand. Thumb Grip Cloth Fastening 4. Turn the palm of your hand upward. 5. Apply the cuff to your left upper arm so the blue stripe is on the inside of your arm and aligned with your middle finger. The air tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" above your elbow.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 22 APPLYING THE ARM CUFF 6. Wrap the cuff firmly in place around your arm using the cloth fastening. APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 5. Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm. The bottom of the cuff should be approximately 1/2'' above your elbow.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 23 TAKING A MEASUREMENT The monitor automatically determines your ideal inflation level. In rare circumstances when a higher inflation may be necessary, the monitor automatically re-inflates the cuff up to 30mmHg higher than the initial inflation and restarts the measurement. 1. Sit on a chair with your feet flat on the floor. Place your arm on a table so the cuff is level with your heart.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 24 TAKING A MEASUREMENT 2. Press the START/STOP button. All display symbols appear on the screen. The cuff starts to inflate automatically. As the cuff inflates, the monitor automatically determines your ideal inflation level. Remain still and do not move your arm until the entire measurement process is completed. ® NOTE: To stop the inflation or measurement, push the START/STOP button. The monitor will stop inflating, start deflating, and will turn off. 3.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 25 TAKING A MEASUREMENT 4. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and pulse rate are displayed. 5. Press the START/STOP button to turn the monitor off. NOTE: The monitor will automatically turn off after five minutes. ® SPECIAL CONDITIONS CAUTION Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 26 USING THE MEMORY FUNCTION Every time you complete a measurement the monitor stores the blood pressure and pulse rate in the memory. The monitor automatically stores up to 90 sets of measurement values (blood pressure and pulse rate). When 90 sets of measurement values are stored, the oldest record is deleted to save the most recent values.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 27 USING THE MEMORY FUNCTION 2. Press the Memory Down button to display the most recent set of measurement values on the screen. to display the oldest set of Press the Memory Up button measurement values. ® Alternating display NOTES: • The date and time are alternately displayed with the measurement values. • Press the button repeatedly to display the next values. • Press and hold the button to display the values faster. 3.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 28 USING THE MEMORY FUNCTION TO DELETE ALL VALUES STORED IN THE MEMORY You cannot partially delete values stored in the memory. All values will be deleted. 1. While holding the Memory Down button , press the START/STOP button down for more than 2 seconds until the display appears as it does in the following illustration. ® 2. Press the START/STOP button to turn the monitor off. NOTE: The monitor will automatically turn off after five minutes.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 29 Care and Maintenance CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Keep the monitor in the storage case when not in use. Make sure the AC Adapter is placed under the main unit so that is does not damage the display. Do not forcefully bend the arm cuff or air tube. Do not fold tightly. Clean the monitor with a soft dry cloth.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 30 CARE AND MAINTENANCE Use the unit in a manner consistent with the instructions provided in this manual. CAUTION Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. CAUTION Changes or modification not approved by the manufacturer will void the user warranty. Do not disassemble or attempt to repair the unit or components.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 31 ERROR INDICATORS AND TROUBLESHOOTING TIPS SYMBOL CAUSE CORRECTION Take another measurement and remain still until the measurement is complete. Monitor could not detect pulse wave. Cuff under-inflated. Cuff not applied correctly. Remove the arm cuff. Read “Taking a Measurement”. Cuff over-inflated. Wait 2-3 minutes. Take another measurement. Replace the four batteries. Refer to “Battery Installation”. Batteries are worn.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 32 ERROR INDICATORS AND TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. Replace all four batteries with new ones. No display appears on the unit. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low. Blood pressure varies constantly. Many factors including stress, time of day, how you wrap the cuff, may affect your blood pressure.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 33 FCC STATEMENT Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 34 WARRANTY LIMITED WARRANTIES Your BP755 IntelliSense® Automatic Blood Pressure Monitor, excluding the arm cuff, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 35 SPECIFICATIONS Model: Display: Measurement Range: Accuracy/Calibration: Inflation: Deflation: Rapid Air Release: Pressure Detection: Measurement Method: Pulse Wave Detection: Power Source: Battery Life: Operating Temperature /Humidity: Storage Temperature /Humidity/Air Pressure: Main Unit Weight: Main Unit Dimensions: Cuff Size: Cuff Circumference: Memory: Contents: BP755 (HEM-7000-Z4CS) LCD Digital Display Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min.
BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Manufactured by OMRON HEALTHCARE Made in China Distributed by: OMRON HEALTHCARE, INC. 1200 Lakeside Drive Bannockburn, Illinois 60015 www.omronhealthcare.com Copyright © 2009 Omron Healthcare, Inc.