NE-C29-E.
NE-C29_main.book Page 2 Tuesday, December 13, 2011 10:40 AM Before using the unit Contents Before using the unit Introduction ................................................................................................... 3 Intended use .................................................................................................. 3 Important safety instructions....................................................................... 4 1. Know your unit ...............................................
NE-C29_main.book Page 3 Tuesday, December 13, 2011 10:40 AM Introduction Thank you for purchasing the OMRON Comp Air Pro. This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, chronic bronchitis, allergies and other respiratory disorders. The compressor forces air to the nebuliser. When the air enters the nebuliser, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled.
NE-C29_main.book Page 4 Tuesday, December 13, 2011 10:40 AM Important safety instructions Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following: Warning: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.
NE-C29_main.book Page 5 Tuesday, December 13, 2011 10:40 AM Important safety instructions • Do not immerse the main unit in water or other liquid. • Do not use or store the device in humid locations, such as a bathroom. • Do not operate the unit with a damaged cord or plug. • Keep the power cord away from heated surfaces. Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” in the Technical Data Section.
NE-C29_main.book Page 6 Tuesday, December 13, 2011 10:40 AM Important safety instructions • To avoid injury to the nose mucosa, do not squeeze the nosepiece into the back of the nose. • Do not block the slit between the cap and the inhalation air inlet. • Do not use a microwave oven or hair dryer to dry the nebulising parts. • Approved for human use only. (Risk of electrical shock) • Always unplug the device from the power outlet after use and before cleaning.
NE-C29_main.book Page 7 Tuesday, December 13, 2011 10:40 AM 1. Know your unit C A D A6 A1 D1 D2 D3 D4 5 3 E A5 E1 E2 A2 A3 B1 E3 A4 B2 E4 B Rear View E5 E6 5 3 A5 A7 E7 A8 A. Compressor (Main Unit) A1.Power Switch A2.Air Connector A3.Filter Cover (* Air filter inside.) A4.Nebuliser Kit Holder A5.Ventilation Slots A6.Storage Compartment Cover A7.Power Cord A8.Power Plug B. Air Tube (PVC, 207cm) B1.Air Plug B2.Air Plug C. Nebulising Parts D. Inhalation Attachments D1.Mouthpiece D2.
NE-C29_main.book Page 8 Tuesday, December 13, 2011 10:40 AM 1. Know your unit Accessories F G F. Spare Air Filters x 5 G. Instruction Manual H H. Warranty Card Material of attachment Nebuliser Kit, Mouthpiece, Nosepiece, Adapter for Child Mask (SEBS): Adult Mask (PVC), Child Mask (PVC): Adult Mask (SEBS), Child Mask (SEBS): Air Tube: Air Filter: Air Filter Cover: • Also applicable Section 10. Optional parts and accessories.
NE-C29_main.book Page 9 Tuesday, December 13, 2011 10:40 AM 2. Guide to using the Comp Air Pro Preparing the Nebuliser for Use (Section 3) Note: Clean and disinfect the nebuliser kit and applicable inhalation attachments before using the device for the first time, or if it has not been used for more than one week. Taking Medication (Section 4) Notes: • Do not tilt the nebuliser kit so that it is at an angle of greater than 45°. • Do not crease or fold the air tube.
NE-C29_main.book Page 10 Tuesday, December 13, 2011 10:40 AM Operating instructions 3. Preparing the nebuliser for use Warning: Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses the same device. For directions on cleaning and disinfecting the parts of the device refer to Section 5 in this instruction manual.
NE-C29_main.book Page 11 Tuesday, December 13, 2011 10:40 AM 3. Preparing the nebuliser for use 5. Remove the vaporiser head from the medication tank. 6. Add the correct amount of prescribed medication to the medication tank. Caution: The capacity of the medication tank is 2 to 7 ml. max 5 3 Note: Scales on the nebuliser kit are for reference only. The scale on the outside of the tank is with vaporiser head in place. The scale on the inside is with no vaporiser head.
NE-C29_main.book Page 12 Tuesday, December 13, 2011 10:40 AM 3. Preparing the nebuliser for use 9. Attach the desired inhalation attachment, as described below. Attaching the mouthpiece Make sure you also attach the cap, when using the mouthpiece. 2 1 1) Attach the cap to the inhalation air inlet. 2) Attach the mouthpiece to the inhalation top. Attaching the adult mask (PVC) Attach the mask to the inhalation top. Note: If the amount of aerosol is too great, attach the cap.
NE-C29_main.book Page 13 Tuesday, December 13, 2011 10:40 AM 3. Preparing the nebuliser for use 10. Attach the air tube. 1) Attach the air tube to the air connector on the compressor. 2) Attach the other end of the air tube to the air tube connector on the medication tank. 2 1 Notes: • Make sure that the air tube is securely attached to the compressor (main unit) and nebuliser kit, and does not come loose.
NE-C29_main.book Page 14 Tuesday, December 13, 2011 10:40 AM 4. Taking medication 1. Hold the nebuliser kit as indicated on the right. max 5 3 Caution: Do not tilt the nebuliser kit so that it is at an angle of greater than 45°. Medication may flow into the mouth. 3 5 ma x 45° 2. Press the power switch to the on ( ) position. The compressor starts and nebulisation starts. Note: Observe whether aerosol is generated. To stop nebulisation Press the power switch to the off ( ) position.
NE-C29_main.book Page 15 Tuesday, December 13, 2011 10:40 AM 4. Taking medication 3. Inhale medication according to your doctor’s and/or health care adviser’s instructions. Using the mouthpiece Prepare your mouthpiece according to Section 3.9. Insert the mouthpiece into your mouth and inhale the medication breathing normally. Exhale as normal through the mouthpiece. max 5 3 Using the nosepiece Prepare your nosepiece according to Section 3.9.
NE-C29_main.book Page 16 Tuesday, December 13, 2011 10:40 AM 4. Taking medication 4. When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet. Power Plug Warning: Condensation may occur in the air tube. Do not store the air tube while it contains condensation or moisture. This could result in infection via bacteria.
NE-C29_main.book Page 17 Tuesday, December 13, 2011 10:40 AM Care and maintenance 5. Cleaning and daily disinfecting 5.1 Cleaning Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulising effectively and also for preventing infections.
NE-C29_main.book Page 18 Tuesday, December 13, 2011 10:40 AM 5. Cleaning and daily disinfecting 7. If the compressor is dirty, wipe it clean with a Mild Detergent soft cloth moistened with water or mild detergent. Caution: The compressor is not waterproof. 8. If the outside of the air tube is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. 9. Store the parts in the storage compartment in the compressor. Note: Make sure that the parts are clean and dry.
NE-C29_main.book Page 19 Tuesday, December 13, 2011 10:40 AM 5. Cleaning and daily disinfecting Handling the Vaporiser Head The vaporiser head is an important part that is used to vaporise medication. Be sure to observe the following precautions when handling it. Caution: • Always wash the vaporiser head after each Baffle use. Failure to do so could cause blockages and a deterioration in your condition due to a failure to vaporise medication effectively. • Do not use a brush or pin etc.
NE-C29_main.book Page 20 Tuesday, December 13, 2011 10:40 AM 6. Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: • Do not leave the unit unattended with infants or persons who cannot express their consent. • Do not subject the device or the parts to any strong shocks such as dropping the device on the floor. • Do not carry or leave the nebuliser while the medication tank contains medication.
NE-C29_main.book Page 21 Tuesday, December 13, 2011 10:40 AM 7. Changing the air filter On average, the air filter should be changed every 60 days or so, or when the filter has changed colour from white. 1. Pull the air filter cover off the compressor. 2. Change the air filter. Remove the old air filter with a sharp object, such as a toothpick, and insert the new air filter. 3. Put the air filter cover back in place. Notes: • Use only OMRON air filters designed for this unit.
NE-C29_main.book Page 22 Tuesday, December 13, 2011 10:40 AM 8. Troubleshooting Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions. Symptom Nothing happens when the power switch is pressed. Cause Remedy Is the power plug plugged into an electrical outlet? Check that the plug is inserted in an electrical outlet. Unplug then reinsert the plug if necessary.
NE-C29_main.book Page 23 Tuesday, December 13, 2011 10:40 AM 9. Technical data Name: Model: Type: Electrical: Power Consumption: Operating Temperature/ Humidity: Storage Temperature/ Humidity/Air Pressure: Weight: Dimensions: Contents: Comp Air Pro OMRON NE-C29-E Non-heating compressor nebuliser 220 - 240V, 50/60 Hz 192VA +10°C to +40°C 30% to 85% RH -20°C to +60°C 10% to 95% RH 700 - 1060 hPa Approx. 2.3kg (compressor only) Approx.
NE-C29_main.book Page 24 Tuesday, December 13, 2011 10:40 AM 9. Technical data Technical data for the OMRON Comp Air Pro compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit: Particle Size: Medication Tank Capacity: Appropriate Medication Quantities: Sound: Nebulisation Rate: Aerosol Output: Aerosol Output Rate: *MMAD **approximately 3µm 7 ml maximum 2 ml minimum - 7 ml maximum Noise level (at 1 m distance) 60 db 0.4 ml/min (by weight loss) **0.4 ml (2ml, 1%NaF) **0.
NE-C29_main.book Page 25 Tuesday, December 13, 2011 10:40 AM 9. Technical data Notes: == Type Type BB • Do not use the device where it may be exposed to flammable gas. • This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device Directive) and the European Standard EN13544-1:2007, Respiratory therapy equipment - Part1: Nebulizing systems and their components.
NE-C29_main.book Page 26 Tuesday, December 13, 2011 10:40 AM 9. Technical data Correct Disposal of This Product (Waste Electrical & Electronic Equipment) This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life.
NE-C29_main.book Page 27 Tuesday, December 13, 2011 10:40 AM 10.Optional parts and accessories Omron V.V.T. Nebuliser Kit Set Air Tube (PVC, 207cm) Mouthpiece Order No. 9956270-0 Order No. 9956273-5 Air Tube (Silicon, 100cm) Nosepiece Order No. 9956269-7 Order No. 9956274-3 Adult Mask (PVC) Child Mask (PVC) Adult Mask (SEBS) Order No. 9956275-1 Order No. 9956276-0 Order No. 9956312-0 Child Mask (SEBS) Set Air Filters (x 5) Filter Cover Order No. 9956281-6 Order No. 9956271-9 Order No.
NE-C29_main.book Page 28 Tuesday, December 13, 2011 10:40 AM 10. Optional parts and accessories Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp THE NETHERLANDS www.omron-healthcare.com Production facility OMRON (DALIAN) CO., LTD. Dalian, CHINA OMRON HEALTHCARE UK LTD. Opal Drive Fox Milne, Milton Keynes, MK15 0DG, U.K.
NE-C29_main.