NE-C801S-E_M_main.book Page 2 Wednesday, January 11, 2012 12:35 PM Before using the device Contents Before using the device Introduction ................................................................................................... 3 Intended use .................................................................................................. 3 Important safety instructions....................................................................... 4 1. Know your unit ....................................
NE-C801S-E_M_main.book Page 3 Wednesday, January 11, 2012 12:35 PM Introduction Thank you for purchasing the OMRON COMP AIR. This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, chronic bronchitis, allergies and other respiratory disorders. The compressor forces air to the nebuliser kit. When the air enters the nebuliser kit, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled.
NE-C801S-E_M_main.book Page 4 Wednesday, January 11, 2012 12:35 PM Important safety instructions Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following: Warning: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.
NE-C801S-E_M_main.book Page 5 Wednesday, January 11, 2012 12:35 PM Important safety instructions • Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device. • Do not operate the device with a damaged power cord or plug. • Keep the power cord away from heated surfaces. • Read and follow the “Important information regarding Electro Magnetic Compatibility (EMC)” (page 27) in the Technical Data Section.
NE-C801S-E_M_main.book Page 6 Wednesday, January 11, 2012 12:35 PM Important safety instructions • Do not block the slit between the cap and the inhalation air inlet. • Do not use a microwave oven or hair dryer to dry the nebulising parts. • Approved for human use only. • If the device is used continuously, the service life of the device may be shortened. • Limit use to 20 minutes at a time, and allow a 40 minute interval before using the device again.
NE-C801S-E_M_main.book Page 7 Wednesday, January 11, 2012 12:35 PM 1.
NE-C801S-E_M_main.book Page 8 Wednesday, January 11, 2012 12:35 PM 1.
NE-C801S-E_M_main.book Page 9 Wednesday, January 11, 2012 12:35 PM Operating instructions 2. Guide to using the device Preparing the Nebuliser for Use - Section 3 (page 10-13) Warning: Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the first time after purchase, or if the device has not been used for a long period of time, or if more than one person uses the same device.
NE-C801S-E_M_main.book Page 10 Wednesday, January 11, 2012 12:35 PM 3. Preparing the nebuliser for use Warning: Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses the same device. For directions on cleaning and disinfecting refer to Section 5 (page 17-21). Note: Make sure that the air filter is changed regularly.
NE-C801S-E_M_main.book Page 11 Wednesday, January 11, 2012 12:35 PM 3. Preparing the nebuliser for use 3.2 Adding medication and assembling the parts 1. Remove the mouthpiece and cap from the nebuliser kit. 2. Remove the inhalation top from the medication tank. 1) Rotate the inhalation top anti-clockwise. 2) Lift the inhalation top out of the medication tank. 3. Add the correct amount of prescribed medication to the medication tank. Caution: The capacity of the medication tank is 2 to 7 ml.
NE-C801S-E_M_main.book Page 12 Wednesday, January 11, 2012 12:35 PM 3. Preparing the nebuliser for use 6. Attach the desired inhalation attachment, as described below. Attaching the mouthpiece 1) Attach the cap to the inhalation air inlet. 2) Attach the mouthpiece to the inhalation top. Attaching the nosepiece 1) Attach the cap to the inhalation air inlet. 2) Attach the nosepiece to the inhalation top. Attaching the adult mask (PVC) Attach the adult mask to the inhalation top.
NE-C801S-E_M_main.book Page 13 Wednesday, January 11, 2012 12:35 PM 3. Preparing the nebuliser for use 7. Attach the air tube. 1) Twist the air tube plug slightly and push it firmly into the air tube connector on the compressor. 2) Twist the air tube plug slightly and push it firmly into the air tube connector on the medication tank. Notes: • Make sure that the air tube is securely attached to the compressor and nebuliser kit, and does not come loose.
NE-C801S-E_M_main.book Page 14 Wednesday, January 11, 2012 12:35 PM 4. Taking medication 1. Hold the nebuliser kit as indicated on the right. Caution: Do not tilt the nebuliser kit at an angle of greater than 45° in all direction. Medication may flow into the mouth. 45° Right angle 45° 2. Press the power switch to the on ( ) position. The compressor starts and nebulisation starts. Note: Observe whether aerosol is generated. To stop nebulisation Press the power switch to the off ( ) position.
NE-C801S-E_M_main.book Page 15 Wednesday, January 11, 2012 12:35 PM 4. Taking medication 3. Inhale medication according to your doctor’s and/or health care adviser’s instructions. Prepare the inhalation attachment according to Section 3 (page 12). Using the mouthpiece Insert the mouthpiece into your mouth and inhale the medication breathing normally. Exhale as normal through the mouthpiece. Using the nosepiece Inhale the medication through the nosepiece, as shown and exhale through the mouth.
NE-C801S-E_M_main.book Page 16 Wednesday, January 11, 2012 12:35 PM 4. Taking medication Care and maintenance 4. When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet. Warning: Condensation may occur in the air tube. Do not store the air tube while it contains condensation or moisture. This could result in infection via bacteria.
NE-C801S-E_M_main.book Page 17 Wednesday, January 11, 2012 12:35 PM 5. Cleaning and daily disinfecting 5.1 Cleaning Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulising effectively and also for preventing infections.
NE-C801S-E_M_main.book Page 18 Wednesday, January 11, 2012 12:35 PM 5. Cleaning and daily disinfecting 7. If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. Caution: The compressor is not waterproof. 8. If the outside of the air tube is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. 9. Reassemble the nebuliser kit. Put it in the storage bag. Note: Nebuliser kit should be replaced after using for one year. 5.
NE-C801S-E_M_main.book Page 19 Wednesday, January 11, 2012 12:35 PM 5. Cleaning and daily disinfecting Handling the Vaporiser Head The vaporiser head is an important part that is used to vaporise medication. Be sure to observe the following precautions when handling it. Caution: • Always wash the vaporiser head after each use. • Do not use a brush or pin etc., to clean the parts. • When disinfecting the parts by boiling, be sure to boil them in plenty of water.
NE-C801S-E_M_main.book Page 20 Wednesday, January 11, 2012 12:35 PM 5. Cleaning and daily disinfecting Use the table below as a guideline to select a method for disinfecting.
NE-C801S-E_M_main.book Page 21 Wednesday, January 11, 2012 12:35 PM 5. Cleaning and daily disinfecting O: applicable ×: not applicable Alcohol Sodium hypochlorite Quaternary ammonium Chlorhexidine Amphoteric surfactant Disinfecting ethanol Milton* (0.1%) Osvan* (0.1%) Hibitane* (0.5%) Tego* (0.
NE-C801S-E_M_main.book Page 22 Wednesday, January 11, 2012 12:35 PM 6. Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: • Do not leave the device unattended with infants or persons who cannot express their consent. • Do not subject the device or the parts to any strong shocks such as dropping the device on the floor.
NE-C801S-E_M_main.book Page 23 Wednesday, January 11, 2012 12:35 PM 7. Changing the air filter If the air filter has changed colour, or has been used on average for more than 60 days, replace it with a new one. 1. Pull the air filter cover off the compressor. 2. Change the air filter. 3. Put the air filter cover back in place. Notes: • Use only OMRON air filters designed for this device. Do not operate without a filter. • There is no front or back orientation for the air filters.
NE-C801S-E_M_main.book Page 24 Wednesday, January 11, 2012 12:35 PM 8. Troubleshooting Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions. Problem Nothing happens when the power switch is pressed. Cause Remedy Check that the plug is Is the AC adapter connected inserted in an electrical correctly to the an electrical outlet. Unplug then reinsert outlet and the compressor? the plug if necessary.
NE-C801S-E_M_main.book Page 25 Wednesday, January 11, 2012 12:35 PM 9. Technical data Product description: Model: Rating (AC adapter): Rating (Compressor Nebuliser): Operating Condition: Operating Temperature/ Humidity: Storage Temperature/ Humidity/Air Pressure: Weight: Dimensions: Contents: Classification: Compressor Nebuliser NE-C801 (NE-C801S-E) 100 - 240V ~ 350mA, 50/60Hz 12V 0.8A Intermittent operation 20min. ON / 40min.
NE-C801S-E_M_main.book Page 26 Wednesday, January 11, 2012 12:35 PM 9. Technical data Technical data for the OMRON NE-C801 Compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit: Particle Size: **MMAD Approx. 3µm MMAD = Mass Median Aerodynamic Diameter Medication Tank Capacity: Appropriate Medication Quantities: Sound: Nebulisation Rate: Aerosol Output: Aerosol Output Rate: 7ml maximum 2ml minimum - 7ml maximum *Approx. 46dB *Approx. 0.3ml/min (by weight loss) **0.
NE-C801S-E_M_main.book Page 27 Wednesday, January 11, 2012 12:35 PM 9. Technical data Important information regarding Electro Magnetic Compatibility (EMC) With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation.
NE-C801S-E_M_main.book Page 28 Wednesday, January 11, 2012 12:35 PM 9. Technical data Correct Disposal of This Product (Waste Electrical & Electronic Equipment) This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life.
NE-C801S-E_M_main.book Page 29 Wednesday, January 11, 2012 12:35 PM 10.Optional parts and accessories Omron V.V.T. Nebuliser Kit N-01 Set Air Tube (PVC, 100cm) Mouthpiece Model: C801S-ATBP-E Order No.: 9515575-2 Model: C28-3P-E Order No.: 9956273-5 Air Tube (Silicone, 100cm) Nosepiece Model: C28-6-E Order No.: 9956269-7 Model: C28-7-E Order No.: 9956274-3 Adult Mask (PVC) Child Mask (PVC) Adult Mask (SEBS) Model: C28-8-E Order No.: 9956275-1 Model: C28-9-E Order No.
NE-C801S-E_M_main.book Page 30 Wednesday, January 11, 2012 12:35 PM 10. Optional parts and accessories Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com Production facility OMRON (DALIAN) CO., LTD. Dalian, CHINA OMRON HEALTHCARE UK LTD. Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.K.