Amplifier Unit Error
Check the status of the indicators after transmission of the test command.
After taking appropriate corrective action, restart the Amplifier Unit, send the test command again and
check again.
If There Is No Response to the Command:
Check the status of the indicators after transmission of the test command.
After taking appropriate corrective action, restart the Amplifier Unit, send the test command again and
check again.
If There Is a Response to the Command:
Check the status of the indicators after transmission of the test command.
After taking appropriate corrective action, restart the Amplifier Unit, send the test command again and
check again.
RUN COMM NORM ERROR Main check points
(If RUN is OFF, the status of the other indica-
tors can be ignored.)
Influence of background noise (change installation position)
Amplifier Unit power supply
If the error cannot be resolved after checking, the Amplifier Unit
may be damaged.
RUN COMM NORM ERROR Main check points
Amplifier Unit baud rate settings
Node numbers of the Amplifier Units (do not match the node
number in the test command)
Connection and wiring of the cable between the host device
and Amplifier Unit
Routing of each cable (influence of background noise)
If the error cannot be resolved after checking, the Amplifier Unit
may be damaged.
Amplifier Unit baud rate settings
Connection and wiring of the cable between the host device
and Amplifier Unit
Routing of the cables (influence of background noise)
RUN COMM NORM ERROR Main check points
Node numbers of the Amplifier Units (The same number is set
for more than one Unit)
If the error cannot be resolved after checking, the Amplifier
Unit may be damaged.
There is a mistake in the command format (number of charac-
ters, character code, etc.).
(Lights once)
(Lights once)