V750-series UHF RFID System Operation Manual Reader/Writer Antenna V750-BA50C04-US (Mono-static Reader/Writer) V740-HS01CA (Circular Antenna) V740-HS01LA (Liner Antenna) Cat. No. SRFM – 012 – A V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
PRECAUTIONS Please read and understand this manual before using the products. Please consult your OMRON representative if you have any question or comments. Warranty, Limitations of Liability WARRANTY: OMRON’S EXCLUSIVE WARRANTY IS THAT THE PRODUCTS ARE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR (OR OTHER PERIOD IF SPECIFIED) FROM DATE OF SALE BY OMRON.
Declarations Regulatory Compliance EMC ................................................................... 47 CFR, Part 15 ................................................................................RSS210 Safety ........................................................................... UL 60950 ....................................................Can/CSA C22.
Safety Precautions This chapter provides important information for the safe use of this product. Ensure to read the information carefully before use. IN THE SAFETY PRECAUTIONS BELOW, SEVERITY IS CATEGORIZED AS EITHER ”WARNING” OR “CAUTION”. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage.
警 WARNING Never disassemble, repair, or modify the main unit and cables. Do not disassemble, repair, or modify this product. Doing so may result in electric shock, fire, or personal injury. Do not handle the device with wet hands. Do not touch the terminals while the device is connected to the power supply. Electric shock hazard. Do not allow the cables to be in contact with heaters. The cable sheaths may melt and the exposed wire may cause electric shock or fire.
CAUTION Do not drop the device you may receive major shocks. Doing so may result in personal injury or device damage. Do not apply strong force to, or place heavy items on the device or cables. Doing so may deform or damage the device, resulting in electric shock or fire. Use and store the product in an environment that is specified in the catalog or operation manual. Failure to do so may cause failure of the device, electric shock, or fire.
Do not allow the device or cables to be exposed to water. Doing so may result in electric shock, fire or failure of non-waterproof devices or cables. If the device fails or is exposed to water (non-waterproof devices or parts), or an unusual smell, smoke, or sparks are detected, immediately refrain from using the device and contact OMRON or a sales representative for service and repair. Continued use of the failed device may result in electric shock or fire. Do not use damaged cables.
To avoid interferences with other systems, adhere to the following items and check them before using the product: -The product uses a publicly available ISM frequency band of 902-928MHz to communicate with Tags. Some transceivers, motors, monitoring devices, power supplies, and other similar RFID systems may generate noise, which cause radio interference and may affect communication with Tags. If the product is required in the vicinity of these items, check for any interferences prior to use.
Table of Contents Feature of V750 series RFID system ..11 1. Installation and Usage Guide ..........15 1.1 Before You Begin.......................................................................................................................15 1.1.1 Installation Requirements.............. 15 1.1.2 Performance Considerations......... 15 1.2 Authorized Antennas .................................................................................................................17 1.2.1 Antennas ..................
3.1.5.3 Reader/Writer operation conditionsエラー! ブックマークが定義されていません。 3.1.5.4 Setting for Communication Conditions エラー! ブックマークが定義されていません。 3.1.5.5 Control Commandエラー! ブックマークが定義されていません。 3.2 Examples ...................................................................................................................................88 3.2.1 Example 1.................................... 88 3.2.2 Example 2 ..................................... 88 3.2.3 Example 3 ..................................... 90 3.2.4 Example 4 .
Feature of V750 series RFID system V750 Series RFID Reader / Writer, Antenna Operation Manual V750-BA50C04-US Mono-static Reader/Writer(4ports) V740-HS01CA V740-HS01LA Mono-static Antenna (Circular) Mono-static Antenna (Liner) The OMRON V750 RFID Reader (herein after denoted as the V750 Reader) uses RFID (radio frequency identification) technology to read data stored on RFID tags. The reader supports UHF (ultra high frequency) antennas, which are available separately.
V750-series Radio wave propatative RFID system is ideal for long range communication and for the system construction used in the production process or distribution control. It is designed to increase “basic performance of communication with tag” and “Quick and simple operability” most as a unique feature. EPC IS Middleware Ethernet OMRON V7 50 V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL OMRON 2006-06, REV.
Main Features 英語内容確認 (1) Various communication performances and functions for various customers’ applications. 1) Selective communication modes to meet various applications. Multi-access: optimizes a sequence automatically according to the number of tags existing in the read field. Single-access: reads a tag in high speed if there is a single tag in the read field. 2) Wide-choice communication condition setting. Multiple communication conditions can be combined for suitable usage..
FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
1. Installation and Usage Guide About this Guide This installation and usage guide explains how to install the V750 Reader, how to use the browser-based interface, and how to control the reader remotely. 1.1 Before You Begin 1.1.1 Installation Requirements • The reader is shipped with a power source with a cable length of 4.2m (13ft9in). • Use only authorized antennas and cables to maintain FCC approval .
• Devices that operate at 900 MHz, such as cordless phones and wireless LANs, can interfere with reader performance. These devices may degrade performance of the reader. The reader may also adversely affect performance of 900 MHz devices. • Antennas operating in close proximity may interfere with one another, thus degrading reader performance.
1.2 Authorized Antennas The antenna authorized by the FCC for use with the V750 Reader is described below. IMPORTANT: No other antennas may be used with the V750 Reader without violating FCC regulations. It is the responsibility of the user to comply with this requirement. 1.2.1 Antennas Mono-static Circular Antenna (Options) Mono-static Liner Antenna (Options) Model: Polarization: Gain: Connector: Cable length: Model: Polarization: Gain: Connector: Cable length: V740-HS01CA Circular 6dBi max.
1.3 Reader Installation The following parts are provided with the reader: Part Quantity Part Number V750-Reader/Writer 1 V750-BA50C04-US Power Supply 1 - I/O Port Connector 1 - IMPORTANT: Be sure the user reads the section on Declarations to maintain compliance with FCC regulations. The Reader and the antennas are to be installed only by professionals at specific locations For human safety maintain a 23 cm (9.1 in) distance from the antennas.
1.3.2 Install the Antennas The antennas can be mounted directly to a variety of surfaces. Mounting surfaces should be flat to fix the antenna securely. To mount the reader on a wall : 1. Hold the antenna in its mounting location and mark the position of the mounting screws with minimum (4) points. The antenna has several mounting holes for each side. Choose 4 of those with diagonal position according to the mounting location. Mounting holes 2.
1.3.3 Connect the Reader LED Indicators Control port Antenna port Mono-Static x 4 DC power input RS-232C Ethernet I/O port Mode switch Interface name and function Name Antenna port ANT1- ANT4 Ethernet port ETHERNET RS-232C port RS-232C Input/Output port IN 1,2,3,4,C OUT 1,2,3,4,C DC Power input POWER DC12V Control port CTRL PORT Mode switch (Not indicated) Function Connects with UHF mono-static type antenna specified by OMRON with attachment cables. Max 4 cables can be connected to.
1.3.4 Antenna Port One to four OMRON Mono-static antennas (V740-HS01CA, V740-HS01LA) can be connected to the reader, depending on the application requirements. 1. Connect required UHF antennas to the antenna ports on the reader . IMPORTANT: Connect antennas to the antenna ports before applying power to the reader. Any antenna port not having an antenna connected to it will be disabled when the reader is powered on.
’’192.168.1.200’’ 4. Plug the power adapter provided with the reader into the DC power input connector. Then connect the AC power cord to a power outlet. While the reader is powering up, 'PWR' LED will turn on. After the reader finishes its power-on self-test, approximately 5 seconds, 'RUN' LED will turn on. The reader is now ready for operation. Connector: Reverse TNC Name SG Signal output GND Ground Function * Prior to connect antenna(s) to the R/W, make sure the power is off.
1.3.5 LED Indicators LED 部 拡大画像 V750 画像 LED Indicators I ndi cat i on Name Col or Descr i pt i on PWR Power Gr een ON Nor mal l y energi zed. RUN Runni ng Gr een ON Nor mal l y r unni ng. Fl ashi ng( 1) Boot pr ocessi ng ( Fl ashi ng shor t i nt er val ) . Fl ashi ng( 2) Saf e Mode r unni ng ( Fl ashi ng l ong i nt er val ) . ON システム異常 機能を実行できない障害が発生している状態 ( ex. H/ W異常) St opped abnormal l y.
I nput / Out put por t ANT2 ANT2 por t connect i ng Yel l ow ON Connect i ng wi t h an ant enna vi a ANT2 i s det ect ed. ( Li ght i ng f or 50ms af t er power ‒ on. ) Means communi cat i on pr ocess i s r unni ng vi a ANT2. ANT3 ANT3 por t connect i ng Yel l ow ON ANT4 ANT4 por t connect i ng Yel l ow ON Connect i ng wi t h an ant enna vi a ANT3 i s det ect ed. ( Li ght i ng f or 50ms af t er power ‒ on. ) Means communi cat i on pr ocess i s r unni ng vi a ANT3.
1.3.6 I/O Interface As an input/ output port, the R/W contains a terminal block of which male connector is removable and attachable with screws. Terminal block connector: MC1.5/10-SFT-3.81 (PHOENIX CONTACT GmbH & Co.
Input specifications Item Number of input Input method Input voltage Input impedance Input current Wiring Specifications 4 i nput s, 1 common i nput Photo coupler DC12〜24V 2.35kΩ TYP. 12V: 4.5mA, 24V: 9.8mA TYP. Wiring with input equipment Filter IN1 Secondary-side internal circuit IN2 IN3 IN4 IN C (Common) Fuse V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
Output specifications Item Number of output Output method Output voltage Output current Wiring Specifications 4 outputs 1 common output Open collector output (Sync type: NPN) 24V max 20mA Wiring with output equipment Filter OUT1 二次側内部回 路 Secondary-side internal circuit OUT2 OUT3 OUT4 OUT C (Common) Fuse V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
1.3.7 RS232C Interface This port is used to connect the R/W to the host containing RS-232CI/F such as PC or PLC. If you use DOS/V computer as a host, prepare a cross cable to connect the PC to the port.
【Sample of connection】 ■ Connecting to the PC: Serial setting is set for “flow control: none”. D-sub 9 pin female (inch screw) contact PC cable Signal Pin Code number CD 1 RD 2 SD 3 ER 4 SG 5 DR 6 RS 7 CS 8 RI 9 D-sub 9pin female (inch screw) contact cable. Pin number 1 2 3 4 5 6 7 8 9 V750 R/W Signal name RD SD SG RS CS ■ Connecting to the Omron’s PLC (programmable logic controller): Serial setting is set for “flow control: none”. D-sub 9 pin male D-sub 9pin female (M2.
1.3.8 Ethernet Interface This port is used to connect the host to the R/W via Ethernet. To connect them, use the commercial cable 10/10Base-T. ■ Connector: RJ-45 (10Pin) LED: LINK(green)/ACT(yellow) LINK --- lights while linking normally. ACT --- lights when detects a carrier.
1.4 Specifications Electrical Reader UHF operating frequency ..............................................................902.75–927.25MHz Input voltage............................................................................................. 12Vdc, 2.3A RF connector type .................................................................................. Reverse-TNC Separate Power Supply Input voltage...............................................................
Supported Tag Protocols 915 MHz ..................................................................................................... EPC GEN2 V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
2. Functions and Control Reference Guide This chapter lays the groundwork for the communication protocol between client software running on a remote computer and the V750 reader. 2.1 System Interface 2.1.1 Command I/F function Via 10/100BaseT Ethernet or RS-232C, the host issues a command to control the R/W. As the control method, V750 employs original procedures. Same commands are used for Ethernet and or RS-232C.
Stop Bit V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 1 / 2bit 2 bit 2006-06, REV.
【コマンド動作一覧】 コマンド種類 経路/返信先 EtherNet 上位機器からの コマンド RS-232C 登録コマンド なし -電源 ON コマンド RS-232C EtherNet -入力起動コマンド レスポンス経路 EtherNet(Port:7090) RS-232C なし(出力制御のみ) RS-232C Ethernet(Port:7090)* 備考 *Connection 確立時 にシステム起動状 態になる。 Operating Mode Operating Mode contains two modes, Operation Mode and Safe Mode. Operation Mode: The R/W works as R/W normally. Safe Mode: The R/W is being under recovering or being maintained after error.
2.1.2 Ethernet Protocol In the current implementation, TCP/IP is used as the transport protocol. TCP is a connection-oriented protocol that provides a reliable, in-order data transport layer with end-to-end checksums and flow control. 2.1.2.1 TCP Connection Setup and Teardown A session between client software and the reader consists of connection setup, data transactions, and connection teardown. At present, all connections are initiated only by the client software.
IP address 192.168.1.100 Subnet mask 255.255.255.0 4. Browse to… http://192.168.1.200 or http://v740 (dhcp name) The V750 reader browser-based interface to the reader is displayed. 5. Click the Set Reader link in the navigation menu. The Modify Settings page appears. 6. If you wish to use DHCP, modify the “Use DHCP?” setting by selecting the “Yes” radio button; otherwise, enter the required network settings in the IP Address, Subnet Mask, and Gateway fields.
2.1.3 Web browser function Via Web browser, you can set following functions, which can perform various works such as indicating an operation state or setting condition, or setting an operation parameter. Item Specification Web browser Communication via Web browser. (Normal) 1.Status Indicates current setting and operation state (current executed command). 2.Query Simple operation window for Tag refresh (Read/Write) 3.Set Reader Specifies operation conditions of the R/W. 4.
2.2 Functions 2.2.1 Command execution Receiving a command from the host via Ethernet or RS-232C, the R/W starts the command execution. You can use following three commands. (1) Reader control command It reads or changes operation control or setting of the R/W. (2) Communication command It triggers to communicate with tag. It executes communication with tag according to the command option or the R/W setting conditions.
(2) Digital output “Programmable output” Following three functions can be assigned to 4 digital outputs respectively. To assign the function, set via Set Operation window of command or Web. User output: outputs ON/OFF state according to the command from the host. Reader state output: outputs operation status of the R/W. Communication results output: output ON/OFF signal depending on the specified judgment after communication process. 2.2.
2.3 Communication 2.3.1 Communication Process Combining following process options, suitable communication procedures can be specified for your application. ■ Process list Item Process contents (Command) Communication sequence (Option) Specifications ID read ID write Data read Data write Lock Kill Single Once Single Repeat Note Reads tag’s ID data. Writes ID data into the tag. Reads tad data (including password). Writes data (including) into tag. Enables lock function in the tag. Disables tag permanently.
2.3.2 Communication Sequence As a way to communication to the tag(s), you can choose a sequence among the following four sequences by specifying with the commands. Name Code Description 1. Single access This method is used for communicating with a single tag in the read field. It can reduce communication process time more than the time under the Multi access mode.
< Operation timing of communication sequence> (1)Single Once The reader communicates with a single tag at a time (1:1 communication). When an antenna detects first tag, the reader returns response and terminates transaction (1 response/ 1 transaction). If the reader does not detect any tag, it repeats the transaction until timeout. In this case, the response indicates “0” as the tag number. If the timeout is specified as “0”, the transaction will repeat until the termination command has been sent.
3) Multi Once The reader reads multiple tags repeating the read transaction until timeout. Upon timeout, it returns all results of communication with tags to the host and finishes the transaction. If the reader does not detect any tag during the reading time, it returns response meaning the number of tag = 0.
2.3.3 Session Setting Following table shows 4 flags as a session flag for communication command. S0 is set as factory default setting for Once command, and S2 is set for Repeat command. Communication option Flag Description Factory default setting. Once S0 In this setting, the reader communicates with all tags existing ・Single Once in the read field whenever a command is executed. ・Multi Once S1/S2/S3 In this setting, the reader communicates with un-read tags (it ignores once-read tags.
2.3.4 Communication Data Control (1) Filtering function Filtering function enables the reader to communicate with selected tags that are suitable for pre-specified conditions. 【Application examples】 - To read pallet tags selectively when item tags and pallet tags are existing together (EPC data). - To read only the selected vender’s tag if there are various kind of venders’ tags (EPC data). - To read the tags that has exclusive data format (the number of PC+EPC bit, NSI).
2.4 Tag Fundamentals Tag Memory Structure Protocols and the tag memory structures supported by the V750 reader are described below. For additional information regarding tag operation, refer to each tag specification. GEN2 Tags GEN2 tags have four memory banks. Kill Password and Access Password are stored in bank 00 (Reserved Area), EPC code is in bank 01 (EPC Area), Tag Identification Memory data that is read only is in bank 10 (TID Area). User data is in bank 11 (User Area).
3. Command Line Interface About this Guide This chapter lays the groundwork for the communication protocol between client software running on a remote computer and the V750 reader. 3.1 Command Interface 3.1.1 Command / Response Frame Structure Ethernet and RS-232C has almost same command structure for command line I/F. Command frame has a Command Code area to control the R/W and Command Data area that is used with Command Code. Terminator that indicates the end of the frame is [LF].
Terminator [CR,0x0d] Indicates the end of the frame with CR,0x0d. No Yes Terminator [LF,0x0a] Indicates the end of the frame with LF,0x0a.
How to calculate FCC in frame for RS-232C. Calculate XOR (Exclusive OR) of figures included in the range of FCD calculation and put the result as a ACSII code at the end of the command.
3.1.2 Command Code List Following is a list of the supported command codes. Each command is represented with four characters. Command Code List Command Command name Code (1) Communication Command (to communicate with tags) Executable in communication? Description RDID Read ID Reads ID data from the tag memory. No WTID Write ID Writes ID data into the tag memory. No Reads data from the tag memory. RDDT Read Data WTDT Write Data LOCK Lock Sets Lock function in the tag.
NOIS Nois measurement Measures noise level of the specified antenna. No (4) Undefined command (in the response frame only) ICMD Illegal Command V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL Command code to be used in the response frame if the R/W receives undefined command. - 2006-06, REV.
3.1.3 Response Code List Response code consisting of four digit figures represents the result of the command execution. Response code helps you speculate a cause of the occurred error. Response Code List Category Response Code Response Name Description Main Sub Normal end 00 00 Normal end The received command ended normally with no error. Command error 10 00 Parity error A parity error has occurred in one of the characters of the command frame (For only RS-232C).
System error 7A 00 Address specification error 7B 00 Data write error During the data write into the detected tag, sufficient power is not supplied to the tag. 7C 1x Antenna At the R/W starts up, an appropriate antenna has not detection error been connected to the specified antenna port. 2x Antenna error Error occurred with the antenna connected to the specified antenna port (even though the antenna is detected normally when start up).
3.1.4 Command / Response Format Following shows a grammar of commands. Command Code and Command Data format in Command Frame Command Data Area Parameter Area Option Area Command Code SP PRM1 SP PRM2 ・・・ PRMn SP OPT1 SP OPT2 ・・・ OPTn 4 Bytes 1 n 1 n n n 1 n 1 n n n Command Code Consists of four characters in ACSII format. This specifies one of the commands described in the Command Code List of 3.1.2.
Command Code, Response Code and Response Data format in Response Frame Response Data Area Command Code Response Code SP DATA1 SP DATA2 ・・・ DATAn 4 Bytes 4 1 n 1 n n n Command Code Set same characters specified as a command sent from the host. Response Code Indicates four-digit hexadecimal numbers. Response Data Returns the some data executed by R/W. Example1: No. of tags for communication commands Example2: The tag ID(s) (or data) read by R/W with Hex code.
3.1.5 Command Specification 3.1.5.1 Communication Command A communication command consists of parameter(s) mandated for command execution and option specified if necessary. Following table shows parameters as an argument of each command and available options.
Lock code shall be specified in 32-bit hexadecimal format as below. (0x not required) ・Format: XXXXXXXX ... XXXXXXXX ※ 32bit 単位との内容を追記!! X: 0 to 9 , A to F When Lock command is executed, this code shall be specified depending on the type of lock. For GEN2 system, 10-digit Lock value shall be specified with 0, 1, * (0 and 1 mean Action and * means MASK) for following five areas; Kill pwd, Access pwd, EPC memory, TID memory, and User memory.
-tif Tag Information Specifies one or more following items as additional information of tag communication results that are output in the response. Specified item(s) shall be returned according to the specified order with commas. ・ ・ ・ ・ ・ -pwd Password -ptc Tag protocol V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL -tif EPC ANT: An antenna number which reads the tag first. CNT: The count of tag read. EPC: EPC code only.
[Note] For setting a timeout value, 100ms or less shall not be specified under the repeat mode (SRP/ MRP). If so, the Reader/Writer may freeze (setting error may occur) depending on the communication performance of the Ethernet or RS-232C. If Ethernet’s traffic is large or the communication speed setting for RS-232C is low, the value shall be set longer. V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
■ Example of command/ response ReaD ID (RDID) Command RDID (S) [options...] Response RDID[RC] (S) [CNT] (S) [ID1 with ITM1] (S)... [IDn with ITMn] [RC] Response Code [CNT] Tag Count [IDn with ITMn] tagID with Items indicated by TIF option. Items are delimited by a comma. If EPC data length is “0” (zero), the ID shall be “*”.
(2) WriTe ID (WTID) Command WTID (S) dat (S)[Options]... Response WTID[RC] (S) [CNT] (S) [ITM1] dat : Data to be written [RC] Response Code [CNT] Tag Count [ITM1] Items indicated by TIF option. Items are delimited by a comma. If EPC/PEP/PER are specified for TIF, EPC data shall be the data before rewrite. If Data length is zero during EPC specification, data shall become ”*”.
(3) ReaD Data (RDDT) Command RDDT(S) mbk (S) dpt (S) dln (S)[options...] mbk: Memory Bank dpt: Data Pointer dln; Data Length Response RDDT[RC] (S) [CNT] (S) [Data1 with ITM1] [RC] Response Code [CNT] Tag Count [Data with ITM] Data with Items indicated by TIF option. Items are delimited by a comma.
(4)WriTe DaTa (WTDT) Command WTDT (S) mbk (S) dpt (S) dln (S) [options...] mbk: Memory Bank dpt: Data Pointer dln; Data Length Response WTDT[RC] (S) [CNT] (S) [ITM1] [RC] Response Code [CNT] Tag Count [ITM1] Items indicated by TIF option. Items are delimited by a comma. *(S) Space Character If EPC/PEP/PER are specified for TIF, EPC data shall be the data before rewrite. If Data length is zero during EPC specification, data shall become ”*”.
(5) LOCK (LOCK) Command LOCK (S) lkc (S) [options...] lkc: Lock Code (10 characters 0/1/*) Response LOCK[RC] (S) [CNT] (S) [ITM1] [RC] Response Code [CNT] Tag Count [ITM1] Items indicated by TIF option. Items are delimited by a comma.
(6)Kill (KILL) Command KILL (S) [options...] Option “pwd” is mandatory. Response KILL[RC] (S) [CNT] (S) [ITM1] [RC] Response Code [CNT] Tag Count [ITM1] Items indicated by TIF option. Items are delimited by a comma.
3.1.5.2 Information of the Reader , Status of the Reader function To setting type of the Reader information and conditions of the Reader function, following items shall be specified in the SET Reader command (SETR) and GET Reader command (GETR). Specifying following option makes setting or read the Reader/Writer function. Information of the Reader is available only for reading data.
RBR RS-232C Baud rate RDT RS-232C Data length RPB RS-232C Parity bit RSB RS-232C Stop bit V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 9.6 (kbps) 19.2 38.4 57.6 7 (bit) 8 N:none O:odd E:even 1 (bit) 2 57.6 (kbps) 7 (bit) E: even 2 (bit) 2006-06, REV.
(1) SET Reader function (SETR) This command writes the functional conditions of the command in process into the nonvolatile memory in the Reader/ Writer. The setting shall be enabled at the upcoming startup. Command Response SETR (S) param1=value1 (S)...param n=value n It specifies a parameter connecting a setting item to a setting value with equal. (The setting item does not have to be prepended with ‘ -‘.
(2) GET Reader (GETR) This command allows the Reader/Writer to read the current functional conditions. Even after SET Reader command (SETR) is executed, the old information shall be read out unless the reboot is completed. Command GETR (S) param1 (S) param2... It specifies a parameter connecting a setting item to a setting value. (‘The setting item does not have to be prepended with ‘ -‘ .) In a single command multiple setting items can be specified by separating with space.
3.1.5.3 Reader/Writer operation conditions Specifying following option in the operation setting command (SETO) or operation read command (GETO) enables to set or read the Reader’s operation conditions. Reader Network Settings (GETR/SETR) Code Content User setting value 0:None CLI Receiver of response 1:Ethernet after command 2:RS-232C execution. IEC Initial Executed Executed command sequence(実行されるコ Command. Executed マンド) command at startup.
OT3 OT4 Output port #3 function setting Output port #4 function setting Same as OT1 (None) Same as OT1 (None) ● If the NML mode is specified in output function setting, you can set conditions by using the following format. Condition(A) Dynamic comparison “DAT”: data (リードしたタグデータ) Condition(B) data “TCT”: tag count (リードしたタグ枚数) Comparison operators “==”:Data match ”!=”:Data unmatch “>=”:data value or more ”<=”:data or less When comparison data is “TCT”, the code is able to be specified.
(1) Set Operation of Reader (SETO: ST Operation) This command is to write operation conditions into the nonvolatile memories in the Reader/Writer. The new setting shall be enabled at the upcoming startup. Command Response SETO (S) param1=value1 Putting equal between a single setting item and a setting value specifies the value (no need to put ‘-‘ before setting item). * Multiple setting items can not be applicable.
(2) Get operation of reader (GETO: GET Operation) This command allows the Reader/Writer to read the current operation conditions. Even after setting operation command (SETO) is executed, the old information shall be read out unless the reboot is completed. Command Response GETO (S) param1 (S) ... param n Specifies a single setting item. (not required ‘-‘ before the item) * Multiple setting items cannot not be specified.
3.1.5.4 Setting for Communication Conditions To setting the conditions to communicate with tags, following items shall be specified in the SET Communication command (SETC) and GET Communication command (GETC). Specifying following option allows the Reader/Writer to set or read the communication condition. To write the setting data into the nonvolatile memories in the Reader/Writer, SAVE communication setting command (SAVE) shall be executed.
V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
(1) SET Communication (SETC) While the command is being executed, setting conditions in the Reader/ Writer are changed. This setting is enabled when another communication command is executed. To write the setting data into the nonvolatile memories in the Reader/Writer, SAVE communication setting command (SAVE) shall be executed. The new setting shall be enabled at the upcoming startup. Command Response SETC (S) param1=value1 (S)...
(2) GET Communication (GETC) This command allows the Reader/ Writer to read the current communication conditions. Just after SET Communication command (SETC) is executed, new information shall be read out. Command GETC (S) param1 (S) param n It specifies a parameter connecting a setting item to a setting value. (‘The setting item does not have to be prepended with ‘ -‘ .) In a single command, multiple setting items can be specified by separating with space.
(3) SAVE communication setting (SAVE) This command allows the Reader/Writer to write communication setting into the nonvolatile memories in the Reader/Writer. If SET Communication command (SETC) is executed and then the Reader/ Writer is started up without executing this command(SAVE), new setting will be abandoned. Command Response SAVE No arguments. * In the future, the function will be extended so that the Reader/Writer can write data into a certain area with specifying the area. ex.
3.1.5.5 Control Command (1)INITialize setting (INIT) Thi s command i ni t i al i zes al l set t i ng of reader so t hat al l set t i ng wi l l r et ur n t o f act or y def aul t set t i ng. Al l set t i ng shal l be wr i t t en i nt o t he i nner nonvol at i l e memor i es. Af t er execut i ng t hi s I NI T command, t he Reader / Wr i t er requi r es r eboot . Command Response INIT No argument ex.
(1) External Input Output control (EXIO) This command allows the Reader /Writer to output ON/OFF to the output terminal and read an input terminal status. If output setting value is omitted, the Reader/Write shall read the input status only.
(2) RESeT (RSET) This command reboots the Reader/Writer after the Reader/ Writer returns the response indicating command receipt. Command Response RESET Nor arguments. * In the future, the function will be extended so that it can specify reset level. ex.
(4) Good BYE (GBYE) - Connection shut down This command enables to shut down connection with Ethernet. This command is valid only when Connection Method is Passive. (Error occurs if the mode is Active.) The communication of response that indicates command receipt is shut down (disconnected?) after sending. Command Response GBYE No argument GBYE0000 Example 1) All setting of the reader shall be initialized to factory default setting.
(6) RERESponse (RERES) This command instructs the Reader/Writer to re-send the latest response data that has been sent. This command shall not be accepted when the other command such as Repeat mode is being processed. REPEAT 系 Command Response RRES No argument (The latest response) Example 1) When the host requests to resend the response for the External Input Output control command (EXIO) that has been executed most lately.
(4) TEST (TEST) This command instructs the Reader/ Writer to return the exact data message just after receiving it from the host. It is to test a communication line. Command TEST (S) TestData Response TEST0000 (S) TestData *(S) Space Character Example 1) When test data “123456789”is entered to check a communication status between the host and the Reader/Writer: [Tx] TEST 1234567890 [Rx] TEST0000 1234567890 V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
(8) Noise level check (NOIS) This command is to check the noise level of specified antenna. Command NOIS (S) antenna antenna: the port number of antenna (1-4) that is to check the noise level. NOIS0000 (S) ch1 (S) ch2 (S) ch3 ・・・ (S) chn ch1-n: Noise level of each communication channel. (S:n=50,EU:n=10,JP:n=9) * Absolute value (not db unit) For the graph via Web site, the level will be plotted with log. *(S) Space Character Example 1) Noise level check for the antenna port 1(US version).
Note: Q A parameter that an Interrogator uses to regulate the probability of Tag response. An Interrogator commands Tags in an inventory round to load a Q-bit random (or pseudo-random) number into their slot counter; the Interrogator may also command Tags to decrement their slot counter. Tags reply when the value in their slot counter (i.e. their slot . see below) is zero. Q is an integer in the range (0,15); the corresponding Tag response probabilities range from 20 = 1 to 2.15 = 0.000031.
3.2 Examples Examples given in this chapter are provided as a guide for the user in determining suitability and does not constitute a warranty. Users must verify operation in their specific environment and application. 3.2.1 Example 1 To read tags attached to cases passed through a gate on a conveyer, the client software finds tags using 2 antennas.
V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
3.2.3 Example 3 To synchronize two readers see the following instructions. On Reader 1: DECLARE cursor_one CURSOR FOR SELECT id FROM tag_id WHERE protocol_id='EPC1' SET time_out=300; SET auto_time cursor_one = '2005-02-01T13:00:00Z', repeat=1000; The first reader will start reading for no less than 300 ms at just 13 o’clock, and it will repeat the command 1000ms.
3.2.4 Example 4 【Syst em exampl e of sel f - oper at i on】 Si mpl i f i ed set t i ng oper at i on pr ovi des l ow- cost syst em. [ 1] Aut omat ed pass check at a por t al gat e. When pr oduct s wi t h t ags pass t hr ough t he por t al , t he R/ W can check whet her i t r eads speci f i ed quant i t y of t ags or not . Then t he R/ W r epor t s t he j udgment ; passi ng OK or not , t o t he operat or .
3.2.
4. Browser-Based Interface About this Guide This installation and usage guide explains how to install the V750 Reader, how to use the browser-based interface, and how to control the reader remotely. 4.
オフライン機能 [ Quer y] [ St at us] [ Set Communi cat i on] [ Set Oper at i on] [ Set Reader ] <Safe Mode 時> OMRON V740 UHF Reader / Wr i t er <Saf e Mode> [St at us] Set Reader Updat e Hel p [ Ut i l i t y] [ Updat e] [ Hel p] V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL OMRON V750 UHF Reader / Wr i t er St at us [Quer y] Set Communi cat i on Set Oper at i on Set Reader Ut i l i t y Updat e Hel p OMRON V750 UHF Reader / Wr i t er St at us Quer y [ Set Communi cat i on] Set Oper at i on Set Reader
4.
(2) Query 画面 実際にコマンドを発信し、実行結果を表示することができる。 実行するコマンドの主なオプションは、すべて画面クリックで選択することができ、コマンド体系を熟 知しないユーザでも簡単に操作することができる。また、コマンドラインを編集することを可能にし、熟 達したユーザが自由にコマンドを実行することもできる。 コマンドオプション選択 コマンド編集領域 実行結果表示領域 V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
(3) Set Reader 画面 リーダの機能情報を表示、設定変更する。 ・リーダ定義 :ユーザー定義のリーダ名称/リーダ役割(設置位置など) ・LAN 設定 :[機能](機能拡張時に対応)、Host、Domain、DHCP、IP Address、Net Mask、Gateway、 [DNS Server]、[Connection Method]、[Default Host/Port]、[NTP Server]、 [SNMP Server] ・RS-232C 設定 :[機能] (機能拡張時に対応※ )、ボーレート、データ構成、[RS/CS 制御有無](機能 拡張時に対応) ※ RS-232C 接続の拡張 I/O 対応など、システム I/F 以外に使用する場合 ・[制御ポート] :機能[スキャン接続、アンテナ切替機、など](機能拡張時に対応) 設定反映ボタン 設定項目 設定ファイル指定 V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL リセットボタン 2006-06, REV.
(4)Set Operation 画面 リーダの動作条件の情報を表示、設定変更する。 ・コマンド実行後返信先 :登録コマンド実行後の返信先− NON/Ethernet/RS-232C ・電源 ON 動作 :実行コマンド列 ・入力1〜4動作 :機能− なし(ユーザ)/コマンド登録、[起動](機能拡張時に対応※ )、実行コマンド 列 ※ 信号立上り時に以外の起動条件に対応した場合 ・出力1〜4動作 :機能− なし(ユーザ)/状態出力/交信結果判断出力、出力時間、条件 (出力時間と条件は機能を交信結果判断出力時に有効) 設定反映ボタン 設定項目 V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
(5) Set Communication 画面 タグとの交信設定条件を表示、設定変更する。 ・Smoothing 機能 :2度読み防止機能、不在レスポンス省略 ・Filtering 機能 :有効/無効、Filtering 条件1− [タグ種類※ ]/パラメータ(MemBank、Pointer、 Length、Data) ※ Gen2 以外のタグの Filtering 機能に対応する場合 ・RF 制御条件 :使用 Session、アンテナ出力レベル、交信実行モード、[LBT 使用]、、[ライト ベリファイ有無] 一斉に設定変更する場合は、所定のフォーマットで項目とその値を記述したファイルをアップロードす ることで、反映させることができる。 各項目の値を記入し、[設定反映ボタン]を押すと、設定が変更される。 [リセットボタン]を押すと、設定値がすべてデフォルト状態に戻される。 設定反映ボタン 設定項目 設定ファイル指定 V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL リセットボタン 2006-06, REV.
(6) Utility 画面 リーダを操作する上で、補助となる以下の 2 つの機能を提供する。 ①Channel RF Monitor 各チャネルでの電波の出力状態をモニタリング表示する。 機能切り替え チャネル状態 ②Log Data 表示 起動後に発生したエラーの履歴を最新エラーログと統計エラーログの種類の形式で表示する。リセッ トにより履歴情報はクリアされる。 最新エラーログでは、直前に発生した最大 32 件のエラーを、実行したコマンドコードとエラーコー ド(4桁)で表示する。 統計エラーログでは、各エラーコード(上2桁)毎に発生した回数を表示する。回数の最大は 65535 回である。これ以上に発生した場合にはカウントアップされない。(下記の画面イメージ) 表示データ選択 ログデータ表示 エラーコード V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL エラー発生回数、発生率 2006-06, REV.
(7) Update 画面 ファームウェアのアップグレード時に、ファームウェアファイルを指定して[更新指示]ボタンを押す ことによりファームウェアを更新する。 ファームウェアファイル指定 更新指示 (8) Help 画面 各画面の操作方法、コマンドオプションの意味などを説明する。 V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
4.3 Safe Mode Use the recessed Safe Mode button on the reader connector panel to recover from errors which prevent the reader from operating in normal mode. In Safe Mode the reader is configured with a static IP address of 192.168.1.200. Safe mode operation restores factory default settings as follows: IP Address: Host Name: 192.168.1.
V750 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
5 Characteristics(Reference) Characteristics data given in this chapter is provided as a guide for the user in determining suitability and does not constitute a warranty. Actual performance may vary based on actual user conditions. 5.1 Communications Range GEN2 Tag Tag is OMRON wave tag. (V750-D22M01) 3m 2m 1m Antenna 1m 2m Antenna X Y Tag *. There are no RF reflection objects around the Antenna and Tag in the measurement environment. *.
5.2 Communications Time The following charts show communication time on each protocol. It is influenced on practical matters, for example radio noise, distance between tags, materials tags are on and other environmental matters. These charts are generated by plotting and linking average of actual communication time on every 5 tags. Communication time is measured in shielded room with one reader, so that no reflection and no interference are considered.
APPENDIX: OUTLINE DRAWINGS Reader / Writer: (V750-BA50C04-US) Material : Aluminium V740 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
Antenna: (V740-HS01LA, V740-HS01CA) Material: Case PVC, Base plate Aluminum V740 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
Antenna Cable: (V740-A01-3.0M, V740-A01-10M) Short cable (V740-A01-3.0M) Long cable ( V740-A01-10M) V740 RFID READER/WRITER, ANTENNA OPERATION MANUAL 2006-06, REV.
Revision History Catalog No. SRFM – 012 – A Revision Code Revision Code A V740 RFID READER/WRITER, ANTENNA OPERATION MANUAL Date 2006/10 Reason for revision/revised page First edition 2006-06, REV.
OMRON CORPORATION RFID BUSINESS DEVELOPMENT DEPARTMENT 14th Fl., Gate City Osaki West Tower 1-11-1 Osaki, Shinagawa-ku, Tokyo 141-0032 Japan Tel: (81)3-5435-2016/Fax: (81)3-5435-2017 Regional Headquarters OMRON ELECTRONICS LLC 1920 Thoreau Drive Suite 165 Schaumburg, IL 60173 U.S.A. Tel: (1)847-303-0780/Fax: (1)847-925-1260 Up-to-date information on RFID Systems can be accessed at OMRON's web site at http://www.omronrfid.com/ Cat. No.