7 - 105
7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-8 Maintenance Commands: Device Information
Execution Examples
Execution with the Following Firmware Versions in the Reader/Writer
Run Mode program version: 1.2.3, Safe Mode program version: 1.2.2
TX: 000000000006FF03D1000006
RX: 00000000000FFF030C000100020003000100020002
Parameter Description
Exception code For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.