UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-9 Maintenance Commands: Log Information
Function
This command clears the log of system errors (fatal errors) that is stored in the Reader/Writer.
Command Format
Response Formats
Normal Response
Error Response
CLEAR SYSTEM ERROR LOG
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8 Byte-9 Byte-10 Byte-11
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Register address Word count
X X 0000 hex 0009 hex FF hex 10 hex D700 hex 0001 hex
Byte-12 Byte-13 Byte-14
Byte
count
Clear type
02 hex 2 bytes
Parameter Description
Register address The register address (D700 hex) that specifies clearing the system error log infor-
mation
Word count The number of words for system error log clear (0001 hex)
Byte count The number of bytes for system error log clear (02 hex)
Clear type 0000 hex: Clear all
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8 Byte-9 Byte-10 Byte-11
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Register address Word count
X X 0000 hex 0006 hex FF hex 10 hex D700 hex 0001 hex
Parameter Description
Register address The register address from the command is set.
Word count The word count from the command is set.
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Excep-
tion code
X X 0000 hex 0003 hex FF hex 90 hex 1 byte
Parameter Description
Exception code For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for