7 Modbus/TCP Communications
7 - 120
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
• Error Response
Execution Examples
Execution with the Following Most Recent Command Error Information in the Reader/Writer
Time information: 09:31:30, IP address: 192.168.1.121, Command code: 0004 hex (WRITE DATA),
Error code: 1005 hex (command parameter error), Attached information: None
TX: 000000000006FF03D900000C
RX:
00000000001BFF031801091F1EC0A8017800000004100500000000000000000000
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Excep-
tion code
X X 0000 hex 0003 hex FF hex 83 hex 1 byte
Parameter Description
Exception code For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for