7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-1 Single-access Communications Commands
• Error Response
Execution Examples
Example 1: Writing 5A5A Hex to Four Words Starting from Word Address 0100 Hex (User Area) in
the RF Tag
TX: 00000000000DFF108100000306310000045A5A
RX: 000000000006FF1081000003
Example 2: Writing 5A5A Hex to the Entire User Area in the RF Tag
TX: 00000000000DFF108100000306300000005A5A
RX: 000000000006FF1081000003
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Excep-
tion code
X X 0000 hex 0003 hex FF hex 90 hex 1 byte
Parameter Description
Exception code For details, refer to Exception Code on page 7-7 under Response Format for Error
Completion on page 7-7.