User's Manual

7 - 51
7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-4 Reader/Writer Control Commands
Function
This command restarts the entire Reader/Writer.
Command Format
Response Formats
Normal Response
Note A response is not returned for forced resetting.
Error Response
Execution Examples
Execution to Restart the Entire Reader/Writer
TX: 000000000009FF10A1000001020000
RX: 000000000006FF10A1000001
RESET
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8 Byte-9 Byte-10 Byte-11
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Register address Word count
X X 0000 hex 0009 hex FF hex 10 hex A100 hex 0001 hex
Byte-12 Byte-13 Byte-14
Byte
count
Options
02 hex 2 bytes
Parameter Description
Register address The register address (A100 hex) that specifies resetting the Reader/Writer.
Word count The number of words for the option (0001 hex)
Byte count The number of option bytes (02 hex)
Options 0001 hex: Repeat
FFFF hex: Forced reset
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8 Byte-9 Byte-10 Byte-11
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Register address Word count
X X 0000 hex 0006 hex FF hex 10 hex A100 hex 0001 hex
Parameter Description
Register address The register address from the command is set.
Word count The word count from the command is set.
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Excep-
tion code
X X 0000 hex 0003 hex FF hex 90 hex 1 byte
Parameter Description
Exception code For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.