User's Manual

7 - 57
7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-5 Reader/Writer Setting Commands: Network Settings
Error Response
Execution Examples
Execution When the Following TCP/IP Communications Conditions Are Set in the Reader/Writer
IP address setting method: Fixed, IP address: 192.168.1.200, Subnet mask: 255.255.255.0, Gate-
way address: 192.168.1.1
TX: 000000000006FF03B0000007
RX: 000000000011FF030E0000C0A801C8FFFFFF00C0A80101
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8
Transaction identi-
fier
Protocol identifier Field length Unit iden-
tifier
Function
code
Excep-
tion code
X X 0000 hex 0003 hex FF hex 83 hex 1 byte
Parameter Description
Exception code For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.