User's Manual
Table Of Contents
- Modbus/TCP Communications
- 7-1 Outline
- 7-2 Message Formats
- 7-3 RF Communications Command Options
- 7-4 Communications Procedure
- 7-5 Commands
- 7-6 V780 Command Details
- 7-6-1 Single-access Communications Commands
- 7-6-2 Multiaccess Communications Commands
- 7-6-3 Modbus Expansion Communications Commands
- 7-6-4 Reader/Writer Control Commands
- 7-6-5 Reader/Writer Setting Commands: Network Settings
- 7-6-6 Reader/Writer Setting Commands: Communications Settings
- 7-6-7 Reader/Writer Setting Commands: Device Settings
- 7-6-8 Maintenance Commands: Device Information
- 7-6-9 Maintenance Commands: Log Information
- 7-6-10 Maintenance Commands: RF Communications Information
7 - 59
7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-5 Reader/Writer Setting Commands: Network Settings
Execution Examples
Execution to Set the Reader/Writer Device Name to V780-A001
TX: 000000000047FF10B10000204056363830532D413030310000000000…00
RX: 000000000006FF10B1000020