User's Manual

7 - 71
7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-6 Reader/Writer Setting Commands: Communications Settings
Error Response
Execution Examples
Execution to Set the Following RF Communications Conditions in the Reader/Writer
RF communications mode: Once, RF communications speed: Auto, RF communications timeout
time: 250 ms, Write verification: Enabled
TX: 000000000011FF10C00000050A0000000000FA00010000
RX: 000000000006FF10C0000005
Byte-0 Byte-1 Byte-2 Byte-3 Byte-4 Byte-5 Byte-6 Byte-7 Byte-8
Transaction identi-
fier
Protocol identifier Field length Unit
identifier
Function
code
Excep-
tion code
X X 0000 hex 0003 hex FF hex 90 hex 1 byte
Parameter Description
Exception code For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.