7 - 95
7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-6 Reader/Writer Setting Commands: Communications Settings
Execution Examples
Example 1: Execution to Set the Following Times in the Reader/Writer
Stop time: 10 ms (000A hex), Continuous transmission time: 400 ms (0190 hex)
TX: 00000000000BFF10C700000204000A0190
RX: 000000000006FF10C7000002
Example 2: Execution to Set the Following Times in the Reader/Writer
Stop time: None, Continuous transmission time: Unlimited
TX: 00000000000BFF10C70000020400000000
RX: 000000000006FF10C7000002
Parameter Description
Exception code For details, refer to Exception Code on page 7-7 under 7-2-3 Response Format for
Error Completion on page 7-7.