User's Manual

7 - 97
7 Modbus/TCP Communications
UHF RFID System V780-series Reader/Writer User’s Manual (Z389)
7-6 V780 Command Details
7
7-6-6 Reader/Writer Setting Commands: Communications Settings
Execution Examples
Execution When the Following RF Transmission Times Are Set in the Reader/Writer
Stop time: 10 ms (000A hex), Continuous transmission time: 400 ms (0190 hex)
TX: 000000000006FF03C7000002
RX: 000000000007FF0304000A0190