Owner's Manual

GUIDE SPECIFICATIONS
On-Q
®
Residential Multimedia Panels
Project Name Project No. Date
Project Location 27 11 16-7 Communications Cabinets, Racks, Frames,
& Enclosures
S. 1-Gang, 2-Port Wall Plate: Catalog No. WP3402-XX two-port keystone wall plate
fabricated from high impact flame retardant plastic with blank keystone cutouts. UL
Listing No. ANSI/UL 1863. Available in white, black, brown, light almond, stainless
steel and ivory. Mounts in installation brackets from manufacturer of wall plate or low
voltage mud rings.
T. 1-Gang, 3-Port Wall Plate: Catalog No. WP3403-XX three-port keystone wall plate
fabricated from high impact flame retardant plastic with blank keystone cutouts. UL
Listing No. ANSI/UL 1863. Available in white, black, brown, light almond, stainless
steel, and ivory. Mounts in installation brackets from manufacturer of wall plate or low
voltage mud rings.
U. 1-Gang, 4-Port Wall Plate: Catalog No. WP3404-XX four-port keystone wall plate
fabricated from high impact flame retardant plastic with blank keystone cutouts. UL
Listing No. ANSI/UL 1863. Available in white, black, brown, light almond, and ivory.
Mounts in installation brackets from manufacturer of wall plate or low voltage mud
rings.
V. 1-Gang, 6-Port Wall Plate: Catalog No. WP3604-XX six-port keystone wall plate
fabricated from high impact flame retardant plastic with blank keystone cutouts. UL
Listing No. ANSI/UL 1863. Available in white, black, brown, light almond, and ivory.
Mounts in installation brackets from manufacturer of wall plate or low voltage mud
rings.
W. 2-Gang, 12-Port Wall Plate: Catalog No. WP3212-XX 12-port keystone wall plate
fabricated from high impact flame retardant plastic with blank keystone cutouts. UL
Listing No. ANSI/UL 1863. Available in white, black, brown, light almond, and ivory.
Mounts in installation brackets from manufacturer of wall plate or low voltage mud
rings.
PART 3 - EXECUTION
3.1 EXAMINATION
Specifier Note: Select either option in the following paragraph and delete the other one.
A. Examine conditions under which residential multimedia panels and components are to
be installed. Notify the [Architect/Engineer] [Construction Manager] in writing of
conditions detrimental to proper completion of the work. Do not proceed with work until
unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Strictly comply with manufacturer's installation instructions and recommendations.
Coordinate installation with adjacent work to ensure proper clearances and to prevent
electrical hazards.
B. Locate panels where indicated on Drawings or directed by Architect/Engineer.
C. Enclosure: For surface mounting, install enclosure on plywood backboard. Use
designated holes in rear of enclosure for permanent mounting using wood screws. For
recessed mounting of enclosure install between studs located at 16 inches o.c. Bend
side tabs out for 1/2-inch gypsum board and secure to studs with appropriate screws.
If a different thickness of gypsum board is used, position enclosure to required depth
using embossed depth marks and screw to studs from inside enclosure.