Datasheet

MC7800, MC7800A, LM340, LM340A Series, NCV7805
http://onsemi.com
6
ELECTRICAL CHARACTERISTICS (continued) (V
in
= 14 V, I
O
= 500 mA, T
J
= T
low
to T
high
[Note 1], unless
otherwise noted.)
MC7808B MC7808C
Characteristic Symbol Min Typ Max Min Typ Max Unit
Ripple Rejection RR 62 56 62 dB
11.5 Vdc V
in
18 Vdc, f = 120 Hz
Dropout Voltage (I
O
= 1.0 A, T
J
= 25°C) V
I
– V
O
2.0 2.0 Vdc
Output Noise Voltage (T
A
= 25°C) V
n
10 10 µV/V
O
10 Hz f 100 kHz
Output Resistance f = 1.0 kHz r
O
0.9 0.9 m
Short Circuit Current Limit (T
A
= 25°C) I
SC
0.2 0.2 A
V
in
= 35 Vdc
Peak Output Current (T
J
= 25°C) I
max
2.2 2.2 A
Average Temperature Coefficient of Output Voltage TCV
O
–0.4 –0.4 mV/°C
ELECTRICAL CHARACTERISTICS (V
in
= 14 V, I
O
= 1.0 A, T
J
= T
low
to T
high
[Note 1], unless otherwise noted.)
MC7808AB/MC7808AC
Characteristic Symbol Min Typ Max Unit
Output Voltage (T
J
= 25°C) V
O
7.84 8.0 8.16 Vdc
Output Voltage (5.0 mA I
O
1.0 A, P
D
15 W) V
O
7.7 8.0 8.3 Vdc
10.6 Vdc V
in
23 Vdc
Line Regulation (Note 2) Reg
line
mV
10.6 Vdc V
in
25 Vdc, I
O
= 500 mA 6.0 15
11 Vdc V
in
17 Vdc, I
O
= 1.0 A 1.7 18
10.4 Vdc V
in
23 Vdc, T
J
= 25°C 5.0 15
Load Regulation (Note 2) Reg
load
mV
5.0 mA I
O
1.5 A, T
J
= 25°C 1.4 25
5.0 mA I
O
1.0 A 1.0 25
250 mA I
O
750 mA 0.22 15
Quiescent Current I
B
3.3 6.0 mA
Quiescent Current Change I
B
mA
11 Vdc V
in
25 Vdc, I
O
= 500 mA 0.8
10.6 Vdc V
in
23 Vdc, I
O
= 1.0 A, T
J
= 25°C 0.8
5.0 mA I
O
1.0 A 0.5
Ripple Rejection RR 56 62 dB
11.5 Vdc V
in
21.5 Vdc, f = 120 Hz, I
O
= 500 mA
Dropout Voltage (I
O
= 1.0 A, T
J
= 25°C) V
I
– V
O
2.0 Vdc
Output Noise Voltage (T
A
= 25°C) V
n
10 µV/V
O
10 Hz f 100 kHz
Output Resistance f = 1.0 kHz r
O
0.9 m
Short Circuit Current Limit (T
A
= 25°C) I
SC
0.2 A
V
in
= 35 Vdc
Peak Output Current (T
J
= 25°C) I
max
2.2 A
Average Temperature Coefficient of Output Voltage TCV
O
–0.4 mV/°C
1. T
low
=0°C for MC78XXAC, C, LM340AT–XX, LM340T–XX T
high
= +125°C for MC78XXAC, C, LM340AT–XX, LM340T–XX, NCV7805
= 40°C for MC78XXB, MC78XXAB, NCV7805
2. Load and line regulation are specified at constant junction temperature. Changes in V
O
due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.