Datasheet

MUR120 Series
http://onsemi.com
2
MAXIMUM RATINGS
Rating Symbol
MUR
Unit
105 110 115 120 130 140 160
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
R
50 100 150 200 300 400 600 V
Average Rectified Forward Current
(Square Wave Mounting Method #3 Per Note 2)
I
F(AV)
1.0 @ T
A
= 130°C 1.0 @ T
A
= 120°C A
Nonrepetitive Peak Surge Current
(Surge applied at rated load conditions, halfwave,
single phase, 60 Hz)
I
FSM
35 A
Operating Junction Temperature and Storage Temperature T
J
, T
stg
*65 to +175 °C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
THERMAL CHARACTERISTICS
Characterisic Symbol Max Unit
Maximum Thermal Resistance, Junction−to−Ambient
R
q
JA
Note 2 °C/W
ELECTRICAL CHARACTERISTICS
Maximum Instantaneous Forward Voltage (Note 1)
(i
F
= 1.0 Amp, T
J
= 150°C)
(i
F
= 1.0 Amp, T
J
= 25°C)
v
F
0.710
0.875
1.05
1.25
V
Maximum Instantaneous Reverse Current (Note 1)
(Rated DC Voltage, T
J
= 150°C)
(Rated DC Voltage, T
J
= 25°C)
i
R
50
2.0
150
5.0
mA
Maximum Reverse Recovery Time
(I
F
= 1.0 A, di/dt = 50 A/ms)
(I
F
= 0.5 A, i
R
= 1.0 A, I
REC
= 0.25 A)
t
rr
35
25
75
50
ns
Maximum Forward Recovery Time
(I
F
= 1.0 A, di/dt = 100 A/ms, I
REC
to 1.0 V)
t
fr
25 50 ns
1. Pulse Test: Pulse Width = 300 ms, Duty Cycle 2.0%.