Data Sheet
MUR405, MUR410, MUR415, MUR420, MUR440, MUR460
www.onsemi.com
2
MAXIMUM RATINGS
Rating Symbol
MUR
Unit
405 410 415 420 440 460
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
R
50 100 150 200 400 600 V
Average Rectified Forward Current (Square Wave)
(Mounting Method #3 Per Note 2)
I
F(AV)
4.0 @ T
A
= 80°C 4.0 @
T
A
= 40°C
A
Nonrepetitive Peak Surge Current
(Surge applied at rated load conditions, half wave, single phase, 60 Hz)
I
FSM
125 110 A
Operating Junction Temperature & Storage Temperature T
J
, T
stg
*65 to +175 °C
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
THERMAL CHARACTERISTICS
Rating Symbol
MUR
Unit
405 410 415 420 440 460
Maximum Thermal Resistance, Junction−to−Ambient
R
q
JA
See Note 2 °C/W
Maximum Thermal Resistance, Junction−to−Case Body
Y
q
JC
6.6 °C/W
ELECTRICAL CHARACTERISTICS
Rating Symbol
MUR
Unit
405 410 415 420 440 460
Maximum Instantaneous Forward Voltage (Note 1)
(i
F
= 3.0 A, T
J
= 150°C)
(i
F
= 3.0 A, T
J
= 25°C)
(i
F
= 4.0 A, T
J
= 25°C)
v
F
0.71
0.88
0.89
1.05
1.25
1.28
V
Maximum Instantaneous Reverse Current (Note 1)
(Rated dc Voltage, T
J
= 150°C)
(Rated dc Voltage, T
J
= 25°C)
i
R
150
5
250
10
mA
Maximum Reverse Recovery Time
(I
F
= 1.0 A, di/dt = 50 A/ms)
(I
F
= 0.5 A, i
R
= 1.0 A, I
REC
= 0.25 A)
t
rr
35
25
75
50
ns
Maximum Forward Recovery Time
(I
F
= 1.0 A, di/dt = 100 A/ms, Recovery to 1.0 V)
t
fr
25 50 ns
Controlled Avalanche Energy (Maximum) W
aval
5 mJ
Typical Peak Reverse Recovery Current
(I
F
= 1.0 A, di/dt = 50 A/ms)
I
RM
0.8 1.7 A
1. Pulse Test: Pulse Width = 300 ms, Duty Cycle v 2.0%.