Datasheet
MUR405, MUR410, MUR415, MUR420, MUR440, MUR460
http://onsemi.com
2
MAXIMUM RATINGS
Rating Symbol
MUR
Unit
405 410 415 420 440 460
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
R
50 100 150 200 400 600 V
Average Rectified Forward Current (Square Wave)
(Mounting Method #3 Per Note 2)
I
F(AV)
4.0 @ T
A
= 80°C 4.0 @
T
A
= 40°C
A
Nonrepetitive Peak Surge Current
(Surge applied at rated load conditions, half wave, single phase, 60 Hz)
I
FSM
125 110 A
Operating Junction Temperature & Storage Temperature T
J
, T
stg
*65 to +175 °C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
THERMAL CHARACTERISTICS
Rating Symbol
MUR
Unit
405 410 415 420 440 460
Maximum Thermal Resistance, Junction−to−Ambient
R
q
JA
See Note 2 °C/W
ELECTRICAL CHARACTERISTICS
Rating Symbol
MUR
Unit
405 410 415 420 440 460
Maximum Instantaneous Forward Voltage (Note 1)
(i
F
= 3.0 A, T
J
= 150°C)
(i
F
= 3.0 A, T
J
= 25°C)
(i
F
= 4.0 A, T
J
= 25°C)
v
F
0.71
0.88
0.89
1.05
1.25
1.28
V
Maximum Instantaneous Reverse Current (Note 1)
(Rated dc Voltage, T
J
= 150°C)
(Rated dc Voltage, T
J
= 25°C)
i
R
150
5
250
10
mA
Maximum Reverse Recovery Time
(I
F
= 1.0 A, di/dt = 50 A/ms)
(I
F
= 0.5 A, i
R
= 1.0 A, I
REC
= 0.25 A)
t
rr
35
25
75
50
ns
Maximum Forward Recovery Time
(I
F
= 1.0 A, di/dt = 100 A/ms, Recovery to 1.0 V)
t
fr
25 50 ns
Controlled Avalanche Energy (Maximum) W
aval
5 mJ
1. Pulse Test: Pulse Width = 300 ms, Duty Cycle v 2.0%.