Datasheet
NCP5612
http://onsemi.com
4
MAXIMUM RATINGS
Rating Symbol Value Unit
Power Supply V
BAT
7.0 V
Output Power Supply Vout 7.0 V
Digital Input Voltage
Digital Input Current
CNTL −0.3 < V < V
BAT
1.0
V
mA
Human Body Model: R = 1500 W, C = 100 pF (Note 3)
Machine Model
ESD 2.0
200
kV
V
LLGA12 Package
Power Dissipation @ T
A
= +85°C (Note 4)
Thermal Resistance, Junction−to−Case
Thermal Resistance, Junction−to−Air
P
D
R
q
JC
R
q
JA
200
51
200
mW
°C/W
°C/W
Operating Ambient Temperature Range T
A
−40 to +85 °C
Operating Junction Temperature Range T
J
−40 to +125 °C
Maximum Junction Temperature T
Jmax
+150 °C
Storage Temperature Range T
stg
−65 to +150 °C
Latch−up Current Maximum Rating per JEDEC Standard: JESD78 − "100 mA
Moisture Sensitivity (Note 5) − 1
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
3. This device series contains ESD protection and exceeds the following tests:
Human Body Model (HBM) "2.0 kV per JEDEC standard: JESD22−A114.
Machine Model (MM) "200 V per JEDEC standard: JESD22−A115.
4. The maximum package power dissipation limit must not be exceeded.
5. Moisture Sensitivity Level (MSL): 1 per IPC/JEDEC standard: J−STD−020A.
POWER SUPPLY SECTION (Typical values are referenced to T
A
= +25°C, Min & Max values are referenced −40°C to +85°C ambient
temperature, operating conditions 2.85 V < V
bat
< 5.5 V, unless otherwise noted.)
Rating Pin Symbol Min Typ Max Unit
Power Supply 11 V
bat
2.7 − 5.5 V
Continuous DC Current in the Load @ V
f
= 3.8 V, 3.2 V < V
bat
< 5.5 V, ICON = L
(30 mA per LED)
7 I
out
60 − −
mA
Output ICON Current (ICON bit = H) @ 3.2 V < V
bat
< 4.2 V, T
A
= +25°C 7 I
ICONTOL
− 450 550 mA
Continuous Output Short Circuit Current 7 I
sch
− 40 100 mA
Output Voltage Compliance (OVP) 7 V
out
4.8 − 5.7 V
DC/DC Start Time (C
out
= 1.0 mF) from end of the CNTL T
dst
delay to full load
operation, @ V
bat
= 3.6 V
12 T
start
− 150 − ms
Output Voltage Turn−off (C
out
= 1 mF) From Last Low Level at CNTL pin to
V
out
= 5%
12 T
off
− 500 − ms
Standby Current, 0°C < T
A
< +85°C
V
bat
= 3.6 V, I
out
= 0 mA, ICON = L
11 I
stdb
− − 1.0 mA
Operating Current, @ I
out
= 0 mA, ICON = H, V
bat
= 3.6 V 11 I
op
− 600 − mA
Output LED to LED Current Matching, V
bat
= 3.6 V,
I
LED
= 10 mA, LED1 & LED2 are Identical −25°C < T
A
< 85°C
2, 3 I
MAT
− "0.2 "1.0 %
Output Current Tolerance @ V
bat
= 3.6 V, I
LED
= 10 mA −25°C < Ta < 85°C 2, 3 I
TOL
− "1.0 − %
Charge Pump Operating Frequency − F
pwr
− 1.0 − MHz
Thermal Shutdown Protection − T
SD
− 160 − °C
Thermal Shutdown Protection Hysteresis − T
SDH
− 30 − °C
Efficiency − LED1 = LED2 = 10 mA, V
f
= 3.2 V, V
bat
= 3.8 V (Total = 20 mA)
Efficiency − LED1 = LED2 = 30 mA, V
f
= 3.75 V, V
bat
= 3.8 V (Total = 60 mA)
−
−
E
PWR
−
−
87
84
−
−
%