HONDURAN SNEEZE Corrugated Asphalt Roofing Panels INSTALLATION INSTRUCTIONS o1g 10T/ Will not rust or corrode like metal ruling s Wind resistant to 180 MPH * Installs aver solid decking, pane purloins, or over shingles Lightweight for easy transporting Limited Lifetime Warranty Color Options BROWN GREEN BLACK The instructions in this manual are intended used when Inst ailing 9 and 10 corrugated panels Begat Pl T Overlap is 4 Inches for all panels
T T ONDURA® should be fearfully installed. Mistakes during the installation prowess can raise problems later and Impact the warranty: Please take the Hume to closely follow these installation guidelines. Installation of roofing materials can be dangerous. Danger typically increases as the steepness of the roof pitch and the height from the ground. Inclement weather conditions and numerous other factors can also contribute to the relative danger.
Installation Stage If possible, we recommend placing the first row of ONDURA® panels on the roof to confirm coverage overlaps before Installation of the panels. PLACEMENT OF ONDURA® PANELS If more than one row of ONDURA® panels is needed, then the panels must be Installed along the eave first. Then additional rows are Installed above the previous row. Stagger the position of the corrugation overlap for each row by starting the second row with a panel that has fewer corrugations.
Installation stage (Continued] FASTENER INSTALLATION Drive ONDULINE® screws only through the crown of the corrugation and always perpendicular to the roof's surface. Be careful not to overdrive the screw. The rubber washer on the screw should snugly contact the panel without dimpling the panel. When appropriately installed, slight hand pressure on an affixed corrugation should not separate the panel from contacting the washer. Install screws on the first panel along the eave and rake edges.
G T e VALLEY FLASHING For valleys, install a minimum 18-inch wide metal valley flashing. Cut sheets at an angle to fit the valley; then tum over, and on the undersides along the valley edge, caulk two corrugations of the 'ONDURA?® closure strip, and place Into the corrugation. Then put a bead of caulking on the flat side of the closure strips and along the corrugation of the sheet between the closure strips.
HONDURAN 'PREMIUM Technical Information s SERIES ww PANELS Corrugations 92 10 10 {1/2 Panel) Length (inches) 79 79 30.5 Width (inches) 345 38 38 Net Coverage Area 15.9 fi2 17.7f2 8.4 fi2 53 panegyric: 5.7 pans /i 12 i Weight (Ibs) 13.0 14.4 7.2 L il 26110 RIDGE CAPS FASTENERS Length 39.5 Inches Length 3 Inches Width 16 inches Head Size cinch Thickness cinch Head Type Hexagonal Surface 441st Container Size 55 Piece Weight 241bs Fasteners per 4040 145+ Weight per sift? 0.5 Ib/ft? 100 sift.