POND KIT WITH LINER 9’ X 6’ 94945 ASSEMBLY AND OPERATING INSTRUCTIONS Due to continuing improvements, actual product may differ slightly from the product described herein. To prevent serious injury, Read and understand all warnings and instructions before use. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com Copyright© 2006 by Harbor Freight Tools®. All rights reserved.
PRODUCT SPECIFICATIONS Pond Liner PE Waterproof Sheet 6.6 Ft. x 9.8 Ft. x .28 mm Pump Voltage Power Consumption 8 Watts, Delivery Volume; Max. 600 I/h, 158 Gal/Hr. Transformer 120 V~, 60 Hz (input), 12 V~, 1100 mA (output) Description of Power Cord 19.6 Ft., Outdoor Cable SAVE THIS MANUAL You will need this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. Keep your invoice with this manual.
5. Use the right tool for the job. Do not attempt to force a small Pump to do the work of a larger industrial Pump. There are certain applications for which this Pump was designed. It will do the job better and more safely at the rate for which it was intended. Do not modify this Pump and do not use this Pump for a purpose for which it was not intended. 6. Maintain Pump with care. Keep Pump and filter clean for better and safer performance. Follow instructions for changing accessories.
ELECTRICAL SAFETY 1. Grounded plugs must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. If the pump for the Pool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user. 2.
10. Use safety equipment. Always wear eye protection. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions. All of these are available at Harbor Freight Tools. USE AND CARE 11. Use clamps (not included) or other practical ways to secure and support the work piece. Holding the work by hand or against your body is unstable and may lead to loss of control. 12.
GROUNDING WARNING! Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use.
DOUBLE INSULATED TOOLS: TOOLS WITH TWO PRONG PLUGS 4. Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and the National Electrical Code. (See Figure B.) 5. Double insulated tools may be used in either of the 120 volt outlets shown in the following illustration. (See Figure B.
6. If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use. 7. Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it. 8. Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
Additional Pump Warnings 1. This pump is intended for clear water fountains only. Not intended for any other use including swimming pools. 2. The National Electric Code requires a ground fault interrupter (GFCI) be used in the circuit supplying power to this pump. Consult an electrician for proper installation. 3. For proper cooling, this pump must be completely submerged. 4. Do not let this pump run dry. 5. Do not use this pump with hot water. Only use fresh, clean water. 6.
Operation General Pond Construction NOTE: For a pond 2 feet deep, the maximum hole size is about 4’ x 7’. This allows for approximately 1 foot of liner to overlap the edge. The deeper the pond, the smaller the hole size must be. 1. Remove the layer of sod if necessary. 2. Dig the hole for the pond. When determining how deep to go, remember that the pump must be elevated on bricks or a platform so that the pump is completely submerged, but the fountain or bell head is above the surface.
OPERATING INSTRUCTIONS (continued) 7. Connect either the Two Tier Fountain Head (4) or the Water Bell Fountain Head (5) to the telescopic tube of the Riser Tube (7). See Figure 1 on page 10. 8. The Riser Tube (7) comes with a Diverter Connector (8) to shut off the flow of water on the side of the outlet. To activate the Diverter (8), turn the Diverter counterclockwise until it clicks. See Figure 1 on page 10. 9. With a few adjustments, the fountain in the Pool is ready for use. 10.
CLEANING THE FILTER IN THE PUMP 1. To clean the Pump Filter, remove the front cover and impeller. See Figure 2. 2. Use a small brush or stream of water to remove any debris. IF THE PUMP FAILS TO OPERATE. CHECK THE CIRCUIT BREAKER OR TRY ANOTHER OUTLET. CHECK THAT THE PUMP IS GETTING ELECTRICAL POWER. 3. If the Pump is used on a dirty surface, raise it slightly to reduce the amount of debris contacting the intake. 4.
INSPECTION, MAINTENANCE, AND CLEANING 1. If the Pump (2) fails to operate, check the circuit breaker and try another outlet. NOTE: Always disconnect from electrical outlet before handling the Pump. 2. Pull apart the Pump as shown in Figure 3. Check the inlet screen to ensure it is not clogged with debris. 3. Remove the Pump to access the Impeller area. Turn the rotor to insure it is not broken or jammed. Re-assemble. 4. Monthly maintenance will add to your Pump’s life.
PARTS LIST Part 1 2 3 4 5 6 7 8 Description Transformer Fountain Pump 2M x 3M Pond Liner Two Tier Fountain Head Water Bell Fountain Head Flow Regulator Riser Tube Diverter Connector Qty. 1 1 1 1 1 1 1 1 2 1 3 5 4 8 7 6 NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts.