Physical and Electrical Data for 5 and 7.5hp Direct Drive Systems.
5hp 1220 max cfm - 2250 cfm w/ typical ductwork
7.5hp 2900 max cfm - 2500 cfm w/ typical ductwork
System Performance
Height w/ 55 Gal. Drum: 132
Footprint: 8.5 x 3
Fan Wheel diameter: 16 Air Foil design
Cyclone Inlet: 10
System Dimensions
TEFC 60 Hz Motor - Single Phase
Insulation Class: F4
Voltage: 230
Amperage: 19.8
Made in U.S.A.
Integral Fan Blower - 5hp
TEFC 60 Hz Motor - Three Phase
Insulation Class: F4
Voltage: 208 - 230 / 460
Amperage: 19.6 - 18.4 / 9.2
Made in U.S.A.
Integral Fan Blower - 7.5hp
Standard: 8 Tube Filters - 5hp, 10 Tube Filters - 7.5hp
Needle felted polyester filter media BIA ZHI / 487 test -
Rated G
Captures 99% of test material over 20 microns
Captures 99.5% of test material between 0.2 - 2.0 microns
@ 11 fpm face velocity
Tube Filter Bags
2 Pleated Cartridges - 260 sq. ft.
Spun Bonded polyester BIA ZH1 / 487 test - Rated C
Captures 99.99% of test material over 20 microns
Captures 99.9% of test material between 0.2 - 2.0 microns
@ 11fpm
External Cartridge Filters (2)
55 Gal. Steel Drums
Large dust bins available
Dust Bin
Angle iron stand for free-standing unit
Silencers available
Magnetic Motor Starters
Options
5 - 7.5 HP Direct Drive Owners Manual
0 2 4 6 8 10 12
Static Pressure (In-H2O)
CFM
- Fan Curve
14 16 18
3000
2500
2000
1500
1000
500
0
3500
4000
3350
2875
2400
2025
1725
1400
1100
760
5hp System - 2000 CFM @ 8 Static Pressure
0 2 4 6 8 10 12
Static Pressure (In-H2O)
CFM
- Fan Curve
14 16 18
3000
2500
2000
1500
1000
500
0
3500
4000
3500
3100
2725
2440
2100
1875
1590
7.5hp System - 2700 CFM @ 8 Static Pressure