User's Manual
Onity HT24W / HT28 Smart  Hardware • 95 
only one lock is configured as the main Suite lock. All other locks of 
the same suite of rooms are configured as Subsuites locks. When using 
this scenario, the guest key that is programmed for the Suite lock, may 
also be configured to open the subsuite locks of the group. A guest key 
made for a subsuite lock may also be configured to open the Suite lock 
of the group. As with the locks in Room mode, the key must have a 
valid site code, room or master code, any applicable authorizations & 
overrides, be within the date and time restraints to gain access to the 
room. 
Any new guest key for the Suite lock will void the previous Suite key 
AND subsuite keys. Any new guest key for a subsuite lock will void 
the previous subsuite key AND the suite key from that particular 
subsuite lock and the suite lock. It will not void OTHER subsuites 
keys from the Suite lock. 
The type of users that may be configured in the keying section of the 
setup program to access the Suite lock are Masters and the Subsuites of 
the group. For the Subsuite lock, Masters and the Suite of the group 
may be configured for access. 
•  Foyer 
When a lock is programmed in Foyer mode, is will open to all keys that 
belong to the system. Additional restrictions can be provided by 
authorizations, date and time constraints. 
The keying section of the setup program is not applicable to Foyer 
locks. 
Note: Previous guest and master codes cannot be voided from a 
Foyer mode lock. The only way a key will be canceled is by the 
expiration date and time. 
•  Selective 
This mode (name in the systems is dependent on the type of system 
used) is used for common access doors, such as exit doors and corridor 
doors, which need to allow access to a range of guest keys and master 
keys. As with the Room, Suite and Subsuite locks, a new key will void 
a previous key. 
When configuring the keying plan of a selective lock, the full range of 
masters AND guest keys is available to grant access to the lock. Up to 
250 users (Guests and Masters) may be configured to access this lock 
without affecting the size of the audit in the lock. If no audit is needed, 
up to 1000 users may be configured to access the lock. 
Standard – 250 Users / 500 Openings 
Extended – 1000 Users / 0 Openings 