User's Manual
Onity HT24W / HT28 Smart Hardware • 113
3. Press the green Enter key.
4. Disconnect the XPP when it is finished.
This lock is now initialized. Make a guest card for the lock and test it. Also, be sure
to test the master card(s).
Read Openings
To view the audit trail of a lock or safe, you must use the READ OPENINGS
function of the XPP.
To read a lock, follow these steps:
1. Go to the desired door and connect the PP.
2. Turn the PP on, enter password if applicable, and select READ
OPENINGS by using the arrow keys.
3. Press the green Enter key.
4. Unplug the PP and take it to the Onity computer to view the openings
on the computer. You can also view the openings directly on the
screen of the XPP, using the Show openings options.
5. Refer to the section on Lock Openings to print this report.
NOTE: You may read the openings of more than one lock. You will be allowed
to select which lock openings to print at the front desk console.
Show Openings
After reading the openings of a lock, it is possible to view those openings directly on
the XPP by selecting the show openings function. If there are multiple openings
reports in the XPP, select the desired report and press Enter to view.
Test Option
The TEST function will test most functions of the lock, including the batteries, the
electronics, and the handle switches. It will also indicate the reason a card was
rejected in a lock. A good time to test each lock is during the time change that occurs
twice each year, since you are at the door with the PP.
To test each lock, follow these steps:
1. Connect the XPP to the lock, turn it on, enter password if applicable,
and select Test Lock using the arrow keys.
2. Press the green Enter key. This will show you the room number of this
lock, the lock type and version, the door number and will test the red
and green lights.
3. Press the Enter key again, this will show the date and time in the lock
and test the batteries. You should see "Batteries OK". If not, replace the
batteries.