Operation Manual

145
Front Panel Rear Panel Remote
Contents
Connections
Playback
Setup
Setting Item Default Value Setting Details
Auto Standby in
HDMI Standby
Through
O Enable or disable "Auto Standby" while "HDMI
Standby Through" is on.
"On": The setting is enabled.
"O": The setting is disabled.
• This setting cannot be set to "On" if "Auto
Standby" and "HDMI Standby Through" are set
to "O".
USB Power Out
at Standby
O When this function is set to "On", electricity can be
supplied to the device connected to the USB port
even if this unit is in standby mode .
• While using this function, power consumption
increases in standby mode, however, the
increase in power consumption is minimized by
automatically entering the HYBRID STANDBY
mode where only the essential circuits are
operating.
Network Standby On When this function is set to "On", you can turn
on the power of the unit via network using an
application such as Onkyo Remote that can control
this unit.
• When "Network Standby" is used, power
consumption increases in standby mode,
however, the increase in power consumption is
minimized by automatically entering the HYBRID
STANDBY mode where only the essential circuits
are operating.
• When connection to the network is lost, "Network
Standby" may be disabled to reduce power
consumption. In such a case, turn the unit on by
using the power button on the remote controller
or main unit.
Setting Item Default Value Setting Details
Bluetooth Wakeup O
This function wakes up the unit on standby by
connecting a BLUETOOTH-enabled device.
"On": When this function is used
"O": When this function is not used
• When this is set to "On", power consumption
increases in standby mode, however, the
increase in power consumption is minimized by
automatically entering the HYBRID STANDBY
mode where only the essential circuits are
operating.
This setting is xed to "O" if "Bluetooth" - "Auto
Input Change" is set to "O".
• Wait for a while if "Network Standby" and "Bluetooth Wakeup" cannot be selected. It can
be selected when the network function is activated.
5. 12V Trigger
Set when outputting the control signal (maximum 12 V/100 mA) through the 12V
TRIGGER OUT jack. You can enable power link operation when you connect the
unit and the external devices equipped with 12V trigger input jack.
Setting Item Default Value Setting Details
Zone Main Set which zone to output the 12V trigger when
playing. If you select "All", then the 12V trigger is
output to all zones that are playing.