Admin app:
WARNING: Remove DC Input
Power and PoE before changing
the voltage of the relays.
Voltage Switches
To power relays without
external supply, select 12V or
24V, and connect locking
hardware to NO/NC and GND
( ). To use external power,
select DRY and use NO/NC
and C, and wire to external
supply.
24V
Provision
1. Open the Admin app
2. Search for org name
3. Press Admin button on SDC
4. Tap Provision in Admin
app and follow instructions
OP Readers
Sensors
Locks
Solid
Blinking
Normal operation
Error state
Solid
Blinking
Solid
Blinking
Active
EOL shorted or cut
Relay is energized
Fault detection
PORT LEDS
Solid White
Blinking Red
Solid Cyan
Solid Yellow
Blinking Yellow
Solid Blue
Solid Purple
Blinking Purple
Solid Red
Normal operation
No Internet
Booting
Restoring software
Updating software
Unprovisioned state
Connected to app
Ready to connect to app
Error, see Control Center
STATUS LED
To set up this device, download the Openpath Admin app at openpath.com/su/adminapp
Output Ratings
• Power Out can supply up to
100mA @ 12V or 50mA @ 24V
• 2 reader ports, max power
output: 250mA @ 12V each
• 2 relays, max power output:
PoE: Max 3W combined output
(250mA @ 12V, 125mA @ 24V)
PoE+: Max 9W combined output
(750mA @ 12V, 375mA @ 24V)
REX
NO
C
NC
STATUS LED
ADMIN BUTTON
SIDE VIEW
power out
relay 1
reader 1
reader 2
wiegand 1
rex 1
contact 1
rex 2
contact 2
relay 2
wiegand 2
power in
24V
12V
NO
C
NC
NO
C
NC
R1
C1
12V
A-
B+
D1
D0
R2
C2
12V
A-
B+
D1
D0
VDC
12V (WET)
24V (WET)
DRY
SD CARD
ETHERNET
ENTRY 1
ENTRY 2
Orange
Violet
Blue
Gray
READER
USB
USB
EXTERNAL
24V
POWER
SUPPLY
+
24V FAIL
SAFE MAG
LOCK
24V locking
hardware
requires PoE
or a 24V
power supply.
12V (WET)
24V (WET)
DRY
External Power Input for backup or if
PoE not available. 12V @ 2A (min) or
24V @ 1A (min). 24V required if locking
hardware requires 24V.
WIEGAND
READER
+
12V FAIL
SECURE
DOOR
STRIKE
DOOR
CONTACT
Mounting Instructions
Install Single Door Controller onto electrical box using provided 6-32 screws or on drywall using provided anchors and
screws.
For a standard US 1-gang box:
1. Use two 6-32 screws (A) to attach backplate (B) to gang box
Recommended: Use the provided drywall screws (C) and anchors (not shown) on drywall for added stability
2. Snap on main housing (D) to backplate (B)
• On the right side of the main housing (D), ensure that the two edge clips fit into
their respective notches on the backplate (B)
• Press firmly on the main housing (D) to snap into place
3. Partially unscrew pre-installed M4 set screw (E) to secure
main housing (D) to backplate (B)
4. Use the cable slot (F) to hold cables while wiring
5. Snap on front cover (G)
End-of-Line Supervision
REX 1-2 and Contact 1-2 have support for
user-installed single or double 1k ohm
termination.
Tamper Sensor
Removal of front cover will trigger tamper
detection during normal operation.
USB Ports
The Single Door Controller has two USB ports that
you can use with Openpath expansion boards.
Expansions require separate power.
SD Slot
Do not remove the SD card unless instructed by Openpath.
WiFi and Device Placement
The Single Door Controller is WiFi-enabled. If using WiFi,
ensure that the SDC is installed within range of an access
point, and is away from sources of noise and interference,
like microwave ovens.
Hard Reset
Warning: Hard Reset will erase all data on device. Only
reset if instructed by Openpath.
1. Remove power
2. Press and hold down Admin button
3. Reconnect power
4. Continue holding Admin button until LED turns solid
yellow (about 30 seconds), then release
STEP 2 VIEW