Datasheet

© TT electronics plc
General Note
TT Electronics reserves the right to make changes in product specicaon without
noce or liability. All informaon is subject to TT Electronics’ own data and is
considered accurate at me of going to print.
OP290 Series
Issue D 07/2016 Page 5
OPTEK Technology, Inc.
1645 Wallace Drive, Carrollton, TX 75006|Ph: +1 972 323 2200
www.optekinc.com | www.electronics.com
Electrical Characteriscs (T
A
= 25° C unless otherwise noted)
SYMBOL PARAMETER MIN TYP MAX UNITS TEST CONDITIONS
Input Diode
E
E (APT)
(2)
Apertured Radiant Incidence
OP290A
OP290B
OP290C
210
180
150
-
-
-
-
300
-
I
F
= 1.50 A
(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the p of the lens.
mW/cm
2
OP291A
OP291C
16
10
-
-
-
-
I
F
= 100 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the p of the lens.
OP292A 2.7 - -
I
F
= 20 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the p of the lens.
OP293A
OP293B
OP293C
16
13
10
-
22
-
-
26
-
I
F
= 100 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the p of the lens.
OP294 0.50 - 1.50
I
F
= 5 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.200” (5.08mm) from the p of the lens.
OP295A
OP295B
44
33
-
-
-
77
I
F
= 1.50 A
(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the p of the lens.
OP296A
OP296B
3.6
2.6
-
-
-
6.6
I
F
= 100 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the p of the lens.
OP297FAB
OP297A
OP297B
2.4
0.7
0.5
-
-
1.0
-
-
1.3
I
F
= 20 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the p of the lens.
OP298A
OP298B
OP298C
3.0
2.4
1.8
-
-
-
-
4.8
-
I
F
= 100 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
0.2” (5.08 mm) from the p of the lens.
OP298AA
OP298AD
3.5
8.5
-
-
-
-
I
F
= 100 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the p of the lens.
OP299 0.15 - 0.45
I
F
= 100 mA
(1)(2)
Measured into a 0.250” [6.35mm] aperture
1.129” (28.7 mm) from the p of the lens.
Electrical Specicaons
Notes:
1. Measurement is taken at the end of a single 100 µs pulse. Heang due to increased pulse rate or pulse width will cause a decrease in reading.
2. Measurement of the average apertured radiant energy incident upon a sensing area 0.250” (6.35 mm) in diameter perpendicular to and centered
on the mechanical axis of the lens and the specied distance from the end of the device. On all models in this series, E
E(APT)
is not necessarily
uniform within the measured area.
3. Measurement is taken at the end of a single 10 ms pulse. Heang due to increased pulse rate or pulse width will cause a decrease in reading.