Spec Sheet

SPECIFICATIONS
DIMENSIONS OPTIONS
Cover for installing
2 units to 1 pole.
1 set
(
2 units
)
HU-3
:
Heating Unit
BC-3
:
Back Cover
PSC-3
:
Pole Side Cover
Heating unit for severe low
temperature conditions
24V DC/AC, 420mA max.
1 set
(
2 units
)
Can be used to cover
mounting pole.
1 set
(
2 units
)
No. 75107-01-14931-0703“Take Care of the Environment” This catalogue uses recycled paper
OPTEX CO., LTD.
(
ISO 9001 Certified by LRQA / ISO14001 Certified by JET
)
5-8-12 Ogoto, Otsu, Shiga, 520-0101 Japan
TEL
+
81
(
0
)
77 579 8670 FAX
+
81
(
0
)
77 579 8190
OPTEX INCORPORATED
(
USA
)
OPTEX
(
EUROPE
)
LTD.
(
UK
)
OPTEX SECURITY SAS
(
FRANCE
)
OPTEX KOREA CO., LTD.
(
KOREA
)
OPTEX SECURITY Sp. z o.o.
(
POLAND
)
OPTEX
(
DONGGUAN
)
CO., LTD.
Shenzhen office
(
CHINA
)
http://www.optexamerica.com
http://www.optexeurope.com
http://www.optex-security.com
http://www.optexkorea.com
http://www.optexchina.com
http://www.optex.co.jp/e
Selectable between 50, 100, 250, and 500m sec.
AX-70TN AX-130TN AX-200TN AX-100TF AX-200TF
Model
Maximum detection range
Maximum arrival range
Detection method
Interruption period
Selectable beam frequency
Power supply
Current consumption
(
transmitter + receiver
)
20m
(
70ft.
)
200m
(
700ft.
)
400m
(
1300ft.
)
600m
(
2000ft.
)
10.5 - 28V DC
Opens when cover is removed at 28V DC, 0.2A max.
-35°C to +60°C
(
-31°F to +140°F
)
Use the optional heating unit
(
HU-3
)
in conditions of -25°C
(
-13°F
)
or below.
300m
(
1000ft.
)
4 channel
600m
(
2000ft.
)
38mA
(
max.
)
41mA
(
max.
)
650g
(
22.9oz.
)
45mA
(
max.
)
44mA
(
max.
)
48mA
(
max.
)
40m
(
130ft.
)
60m
(
200ft.
)
30m
(
100ft.
)
60m
(
200ft.
)
Infrared beam interruption detection
170
(
6.7
)
65
(
2.6
)
69.5
(
2.7
)
83.5
(
3.3
)
36
(
1.4
)
Dimensions : mm
(
inches
)
The Best Short Range Photoelectric Detector
AX-TN/TF series is a compact photoelectric detector with "the IP65 high durability", and
"stable detection performance".
These features reduce false alarms drastically caused by outdoor severe environmental changes and
provide a wide range of applications.
AX
-
70
/
130
/
200TN
AX
-
100
/
200TF
(
STANDARD MODEL
)
(
ENHANCED MODEL
)
SHORT RANGE PHOTOELECTRIC DETECTOR
Alarm period 2sec.
(
±1
)
nominal
D.Q. output
Alarm output
Tamper switch
Operating humidity
Alignment angle
Operating temperature
N.C. 28V DC, 0.2A
(
max.
)
N.C. 28V DC, 0.2A
(
max.
)
N.C./N.O. 28V DC, 0.2A
(
max.
)
700g
(
24.7oz.
)
95% max.
± 90° Horizontal, ± 5° Vertical
Mounting
Weight
(
transmitter + receiver
)
Housing protection
(
EN00529
)
Wall and pole mounting
IP65
*Specifications and design are subject to change without prior notice.
NOTE: These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or