14.2 ADT Focus 200 Plus / Focus Cadet Control Panel Zone Information
Examples of programming for alarm points:
Note: For UL installations, the control panel must be programmed to indicate an alarm if the system is in an armed condition and an RF jamming signal
occurs at the receiver.
EN4232MR Output Function Point # Point Name Point Type Description Option
Alarm 1 1
Alarm 2 2
Repeater AC Loss 3 RF REPEATER AC 13 (SPV) Supervisory
RF Point Low Battery 4 RF PT LOW BATT 13 (SPV) Supervisory
RF Point/Receiver Tamper 5 RF PT TROUBLE 1 (FI) Fixed 2
RF Point Inactive 6 RF PT INACTIVE 13 (SPV) Supervisory
Receiver Power Loss 7 RF RECVR POWER 1 (FI) Fixed 2
RF Jam 8 RF SYSTEM JAMMED 13 (SPV) Supervisory
EN4232MR Output Function Point # Point Name Point Type Description Option
Intrusion Front Door 7 (MIC) Movable Instant Chime 2
or
8 (MDC) Movable Delayed Chime 2
Holdup Holdup 11 (HU) Holdup 2