User Manual
Table Of Contents
- Notice
- Document Part Number
- Trademarks
- Technical Services Contact Information
- Document Conventions
- EN6080 Area Control Gateway Overview
- 1.1 Introduction
- 1.2 Recommended System Requirements
- 1.3 EN6080 Area Control Gateway Initial Setup and Connection
- 1.3.1 Configure Network Settings (for Windows 7)
- 1.3.2 Disable Delayed ACK Mode on the Windows® 7 Operating System
- 1.3.3 Browse to the EN6080 Area Control Gateway Web Server Screens
- 1.3.4 License Key Setup
- Home
- 2.1 Home
- 2.1.1 System Connection Summary
- 2.1.2 Device Information
- 2.2 Site Information
- 2.2.1 ACG Information
- 2.2.2 Contact Information
- ACG Setup
- 3.1 User Administration
- 3.1.1 Update User or Admin Password
- 3.2 IP Administration
- 3.2.1 Configure a Static IP Address
- 3.2.2 Configure a DHCP IP Address
- 3.3 Date and Time Setup
- 3.3.1 Poll NTP Servers for Time and Date
- 3.3.2 Synchronize Time and Date with your PC
- Partitions
- 4.1 Partitions
- 4.2 Define a New Partition
- 4.3 Assign Devices to a Partition
- 4.4 Remove Devices from a Partition
- 4.5 Update a Partition
- 4.6 Delete a Partition
- Wireless Setup
- 5.1 Wireless Setup
- 5.1.1 Update the NID
- Device Setup
- 6.1 Manual Administration
- 6.1.1 Manually Register a Device
- 6.1.2 Unregister a Registered Device
- 6.2 Automatic Administration
- 6.2.1 Start Discovery
- 6.2.2 Edit and Register the Devices
- 6.2.3 Unregister a Registered Device
- 6.3 Upload Administration
- 6.3.1 Upload a Spreadsheet of Devices to Register
- Logs
- 7.1 Logs
- 7.2 Alarm Logs
- 7.2.1 Retrieve and Save Logs
- 7.3 System Logs
- 7.3.1 Retrieve and Save System Logs
- 7.4 Trouble Logs
- 7.4.1 Retrieve and Save Trouble Logs
- File Management
- 8.1 System and Configuration Files
- 8.1.1 Back Up Configuration Files
- 8.1.2 Restore Configuration Files
- 8.2 Firmware Update
- 8.2.1 Update Firmware
ACG Setup
7/28/17 06443H © 2017, Inovonics - www.inovonics.com 18
3.2 IP Administration
The IP administration screen is used to configure the IP address of the
EN6080 area control gateway. It is only accessible to admin level users.
Figure 3-2 EN6080 area control gateway IP setup screen
3.2.1 Configure a Static IP Address
By default, the EN6080 is configured with a static IP of 192.168.60.80 and a
subnet mask of 255.255.255.0. Before configuring the IP address, you will
need to obtain a known good static IP address, subnet mask, and gateway on
the target network from your IP administrator.
To configure a static IP address:
1. Select “Static” to choose a static IP address for the EN6080 area control
gateway.
2. Enter the known good IP address in the “IP:” field.
3. Enter the subnet mask of the IP network in the “Subnet:” field.
4. Enter the gateway for this IP network in the “Gateway:” field.
5. Click “Update” to configure the EN6080 area control gateway IP address.