User Manual
Table Of Contents
- Notice
- Document Part Number
- Trademarks
- Technical Services Contact Information
- Document Conventions
- EN6080 Area Control Gateway Overview
- 1.1 Introduction
- 1.2 Recommended System Requirements
- 1.3 EN6080 Area Control Gateway Initial Setup and Connection
- 1.3.1 Configure Network Settings (for Windows 7)
- 1.3.2 Disable Delayed ACK Mode on the Windows® 7 Operating System
- 1.3.3 Browse to the EN6080 Area Control Gateway Web Server Screens
- 1.3.4 License Key Setup
- Home
- 2.1 Home
- 2.1.1 System Connection Summary
- 2.1.2 Device Information
- 2.2 Site Information
- 2.2.1 ACG Information
- 2.2.2 Contact Information
- ACG Setup
- 3.1 User Administration
- 3.1.1 Update User or Admin Password
- 3.2 IP Administration
- 3.2.1 Configure a Static IP Address
- 3.2.2 Configure a DHCP IP Address
- 3.3 Date and Time Setup
- 3.3.1 Poll NTP Servers for Time and Date
- 3.3.2 Synchronize Time and Date with your PC
- Partitions
- 4.1 Partitions
- 4.2 Define a New Partition
- 4.3 Assign Devices to a Partition
- 4.4 Remove Devices from a Partition
- 4.5 Update a Partition
- 4.6 Delete a Partition
- Wireless Setup
- 5.1 Wireless Setup
- 5.1.1 Update the NID
- Device Setup
- 6.1 Manual Administration
- 6.1.1 Manually Register a Device
- 6.1.2 Unregister a Registered Device
- 6.2 Automatic Administration
- 6.2.1 Start Discovery
- 6.2.2 Edit and Register the Devices
- 6.2.3 Unregister a Registered Device
- 6.3 Upload Administration
- 6.3.1 Upload a Spreadsheet of Devices to Register
- Logs
- 7.1 Logs
- 7.2 Alarm Logs
- 7.2.1 Retrieve and Save Logs
- 7.3 System Logs
- 7.3.1 Retrieve and Save System Logs
- 7.4 Trouble Logs
- 7.4.1 Retrieve and Save Trouble Logs
- File Management
- 8.1 System and Configuration Files
- 8.1.1 Back Up Configuration Files
- 8.1.2 Restore Configuration Files
- 8.2 Firmware Update
- 8.2.1 Update Firmware
ACG Setup
7/28/17 06443H © 2017, Inovonics - www.inovonics.com 20
3.3 Date and Time Setup
Caution: The backup battery must be installed in the EN6080 at all times and the time
must be set on startup. This preserves the accuracy of the logs and ensures
all features work correctly.
The EN6080 area control gateway contains a real time clock that is used to tag
events and log entries. The date and time setup screen is used to configure
the date and time of that clock. It is only accessible to admin level users. The
area control gateway can either poll the Network Time Protocol servers to
automatically synchronize the time and date, or synchronize time and date
with the computer connected to the EN6080.
If the time reported by the EN6080 area control gateway differs from the time
setting on the computer by more than five seconds, it will be reported on the
home page. Discrepancies as small as one second will be reported on the date
and time setup page.
Figure 3-4 EN6080 area control date and time setup screen