ACG Setup
7/28/17 06443H © 2017, Inovonics - www.inovonics.com 20
3.3 Date and Time Setup
Caution: The backup battery must be installed in the EN6080 at all times and the time
must be set on startup. This preserves the accuracy of the logs and ensures
all features work correctly.
The EN6080 area control gateway contains a real time clock that is used to tag
events and log entries. The date and time setup screen is used to configure
the date and time of that clock. It is only accessible to admin level users. The
area control gateway can either poll the Network Time Protocol servers to
automatically synchronize the time and date, or synchronize time and date
with the computer connected to the EN6080.
If the time reported by the EN6080 area control gateway differs from the time
setting on the computer by more than five seconds, it will be reported on the
home page. Discrepancies as small as one second will be reported on the date
and time setup page.
Figure 3-4 EN6080 area control date and time setup screen