User Manual
Table Of Contents
- Notice
- Document Part Number
- Trademarks
- Technical Services Contact Information
- Document Conventions
- EN6080 Area Control Gateway Overview
- 1.1 Introduction
- 1.2 Recommended System Requirements
- 1.3 EN6080 Area Control Gateway Initial Setup and Connection
- 1.3.1 Configure Network Settings (for Windows 7)
- 1.3.2 Disable Delayed ACK Mode on the Windows® 7 Operating System
- 1.3.3 Browse to the EN6080 Area Control Gateway Web Server Screens
- 1.3.4 License Key Setup
- Home
- 2.1 Home
- 2.1.1 System Connection Summary
- 2.1.2 Device Information
- 2.2 Site Information
- 2.2.1 ACG Information
- 2.2.2 Contact Information
- ACG Setup
- 3.1 User Administration
- 3.1.1 Update User or Admin Password
- 3.2 IP Administration
- 3.2.1 Configure a Static IP Address
- 3.2.2 Configure a DHCP IP Address
- 3.3 Date and Time Setup
- 3.3.1 Poll NTP Servers for Time and Date
- 3.3.2 Synchronize Time and Date with your PC
- Partitions
- 4.1 Partitions
- 4.2 Define a New Partition
- 4.3 Assign Devices to a Partition
- 4.4 Remove Devices from a Partition
- 4.5 Update a Partition
- 4.6 Delete a Partition
- Wireless Setup
- 5.1 Wireless Setup
- 5.1.1 Update the NID
- Device Setup
- 6.1 Manual Administration
- 6.1.1 Manually Register a Device
- 6.1.2 Unregister a Registered Device
- 6.2 Automatic Administration
- 6.2.1 Start Discovery
- 6.2.2 Edit and Register the Devices
- 6.2.3 Unregister a Registered Device
- 6.3 Upload Administration
- 6.3.1 Upload a Spreadsheet of Devices to Register
- Logs
- 7.1 Logs
- 7.2 Alarm Logs
- 7.2.1 Retrieve and Save Logs
- 7.3 System Logs
- 7.3.1 Retrieve and Save System Logs
- 7.4 Trouble Logs
- 7.4.1 Retrieve and Save Trouble Logs
- File Management
- 8.1 System and Configuration Files
- 8.1.1 Back Up Configuration Files
- 8.1.2 Restore Configuration Files
- 8.2 Firmware Update
- 8.2.1 Update Firmware
Partitions
7/28/17 06443H © 2017, Inovonics - www.inovonics.com 25
4.2 Define a New Partition
To define a new partition:
1. Click “Define New.”
2. Enter a descriptive name for the partition in the pop-up text field. The
name can be up to 63 characters.
3. Click “Create.”
The first partition will be created starting with an ID of “1.” Additional partitions
will be created with sequentially increasing IDs.
4.3 Assign Devices to a Partition
The create and assign partition field displays all devices in the system and
allows them to be added and removed from partitions. Each device can be
assigned to up to four partitions, so they can be managed separately. For
instance, a door contact transmitter mounted on the door to a pharmacy in a
supermarket might be assigned to both a “pharmacy” and a “building” partition.
That way one could manage the pharmacy separately from the rest of the
building, or manage the entire building as a whole.
To assign devices to a partition:
1. Click the checkbox next to all devices you wish to assign to the partition.
2. Select the partition to which you wish to assign the devices.
3. Click the “Assign to Partition” button.
4.4 Remove Devices from a Partition
To remove devices from a partition:
1. Click the checkbox next to all devices you wish to remove from a partition.
2. Select the partition from which you wish to remove the end devices.
3. Click the “Remove from Partition” button.