Manual

-11-
Dip switch
2
TEST
(factory default)
POSITION
FUNCTION
NORM.
•LED will lights at the time of detection regardless
DIP-SW 6.
(Lights up irrespective of the LED ON/OFF (DIP-
SW 6, see p13) setting)
•Alarm will be generated at the time of detection
regardless DIP-SW 2.
•Normal operation. (Battery saving mode.)
•LED is off. (When LED ON/OFF is OFF.)
120s
(factory default)
POSITION
FUNCTION
5s
120 seconds
5 seconds.
5s
120s
Dip switch
1
SETTING
4
Dip SW
1 WALK TEST MODE
2 BATTERY SAVING TIMER
3 IMMUNITY
4 TROUBLE OUTPUT TYPE
5 TROUBLE OUTPUT TERMINAL
6 LED ON/OFF
ANTI-MASKING
SENSITIVITY
PIR SENSITIVITY
Do not touch
TEST
NORM.
Caution>>
After completing a walk test, always set the unit to NORM position for
operation. Using the unit in TEST mode will shorten the battery life.
NOTE: For the walk test, move more than 1m(3.3ft.) away from the
detector.
Even if there are continuous alarm events, the alarm is generated
only once in the timer period to save the battery life.
(p13)
(p13)
-WALK TEST MODE
-BATTERY SAVING TIMER
4-1
FUNCTION
STD
(factory default)
POSITION
FUNCTION
IMMUNITY
Normal sensitivity.
Sensitivity will be relaxed under the hostile
environment.
IMMUNITY
STD
Dip switch
3
-IMMUNITY SWITCH