Door interface
IVPC-DI
This guide covers the installation and setup for the door interface unit of the IVPC system. The IVPC-DI can be used
as a chime, dry relay output, or both. Common applications are for switching power to a maglock or a door strike.
Please see the example circuits below for ideas.
Introduction
General Information
Mode switch
Pairing switch
Volume +/- button
(mute and 3 steps)
LED indicator
Speaker
Terminal; Power input
Mounting plate
Terminal; Relay output
- During volume adjustment, the default type of
tone sounds regardless the selected type of tone.
- A confirmation beep sounds when the unit is muted.
What to expect
Mounting and wiring;
mount the IVPC-DI, connect power wires and signal wires to external devices.
Pairing;
pair the IVPC-DI to the IVPC-DS, using the IVPC-MS or using the OPTEX Vision App.
Operation check;
test the performance of the IVPC-DI and external devices of the system.
1
2
3
- 1 -
COM
N.O.
COM
Magnetic Lock
Door Strike
N.C.
<<
Relay output wiring examples
>>
<<
LED indications
>>
Power on
(Before pairing)
Power on
(Pairing completed)
Pairing success
[tone 1]
Pairing failure
[Beeps]
Tone/unlock
[tone 1 to 5, or mute]
<<
Parts indications
>>
Power supply
Power supply
Screws & anchors
< Accessories >
Blinking (Red)
Solid light (White)
Blinking (Blue)
Blinking (Red)
Blink once (Red)
EN