PARTS LAYOUT INSIDE THE COVER AND THEIR FUNCTIONS
4
3-5
INSTALLING AT AN ANGLE TO POLE
When installing the product at an angle to a pole, use the optional
adjustable angle mounting bracket for pole (RLS-SB).
1 Take steps
1
and
2
in “3-1” to remove the cover and
mounting bracket.
2 Fix the optional adjustable angle mounting bracket to the
pole using 2 stainless belts (included in the adjustable angle
mounting bracket).
3 Fix the mounting bracket with 4 lock screws with the washer
attached to the optional adjustable angle mounting bracket.
4 Take step
6
in “3-1” to install and fix the main unit to the
mounting bracket.
5 Take steps
7
through
9
in “3-1” to do wiring, check the
setup and operation, and then install the cover.
4-1
WIRING
Power wires should not exceed the following lengths.
WIRE
SIZE
24V DC 24V AC
AWG20
(0.52 mm
2
)
120
(394)
60
(197)
AWG18
(0.83 mm
2
)
200
(656)
100
(328)
m (ft.)
4-2
RESET SWITCH
This switch is used for restarting the system.
Do not touch it during normal operation.
4-3
SIGNAL OUTPUT
-D.Q. output
The algorithm specific to REDSCAN allows
detecting an intrusion amid the fog. However,
during severe conditions such as heavy rain,
dense fog or snow storms the Environmental
DisQualification (EDQ) output is activated.
-Alarm output
Upon detecting an intruder, this product outputs the alarm specific
to the area (Area A1, Area A2, Area B1 or Area B2) where the
intrusion happened.
When combined with an area monitoring system using a PTZ
camera, this product works efficiently to provide early detection of
intruders.
-Tamper output
This output is enabled when the terminal cover is
removed.
-Trouble output
It is generated when an error has occurred on the
sensor.
Name Function
Anti-masking
It is activated when an obstacle
has been placed in front of the
sensor in order to block the
detection area. It is reset after
such obstacles are removed.
Heavy soiling of the front
window can also activate this
function.
Anti-rotation
This function is activated
when the area being scanned
changes by a signicant
amount as a result of the unit
being rotated from its original
settings. Not applicable in
Manual mode.
Sensor error
It is activated when the sensor
has detected an internal self
check error.
-Alarm output
The alarm output is generated if an intruder is
detected in one or more of the divided areas (Area
A1, Area A2, Area B1 and Area B2).
Stainless belt
(included in the
pole mounting
bracket)
Adjustable angle
mounting bracket
D.Q OUTPUT (N.C.)
D.Q OUTPUT (N.O.)
A2 area ALARM OUTPUT (N.O.)
A1 area ALARM OUTPUT (N.O.)
B1 area ALARM OUTPUT (N.O.)
B2 area ALARM OUTPUT (N.O.)
TAMPER OUTPUT (N.C.)
TROUBLE OUTPUT (N.O.)
TROUBLE OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
ALARM OUTPUT (N.C.)
POWER INPUT
WALK TESTER
CONNECTOR
MAINTENANCE
CONNECTOR
RESET
Switch
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
Wires must be stripped back 9 mm.
Use the gauge on the panel for
correct measurement.
Stripped wire length