Manual
- 8 -
- 9 -
REDWAVE
REDWAVE
MICROWAVE
REDWAVE
ALARM OUTPUT
CELL BATTERY
POWER
SUPPLY
FROM
SENSOR
POWER OFF
REDWAVE
PIR NEAR
REDWAVE
PIR FAR
MEGARED
FAR
MEGARED
NEAR
REDWALL
REDWIDE
WALKTESTER
REDWALL
REDWIDE
MEGARED
CONNECTION
SELECT
SWITCH
MODE
SELECT
SWITCH
POWER
SELECT
SWITCH
OPM-WT
Set A2
Power
A1
B1 B2
Status
Set A2
Powe
r
A1
B1 B2
Status
F
in
e
adj.
A
u
t
o F
u
n
c
.
S
e
t
P1
P2
H1
V
H2
O
f
f
s
e
t
S
e
n
s
.
H
M
L
S
i
z
e
S
M
L
A
r
e
a
A
A2
Powe
r
-1 +
1
-1 +
1
-1 0
A1
B
1
B
2
A
r
e
a
B
5
7
3
1
2
4
0
Status
Range
M
o
d
e
M
A
0
8
1
6
2
4
4
1
2
2
0
2
8
0
4
8
1
2
1
6
2
0
2
4
2
8
7
7
Fine
adj.
Auto Func. Set
P1
P2
H1
V
H2
Offset
Sens.
H
M
L
Size
S
M
L
Area A
A2
Power
-1 +1 -1 +1 -1 0
A1
B1 B2
Area B
5731240
Status
Range
Mode
M
A
0
8
16
24
4
12
20
28
0
4
8
12
16
20
24
28
7
7
Set A2
Powe
r
A1
B1 B2
Status
SETTING HORIZONTAL DETECTION AREAS 1 AND 2
5
4-4
CONNECTING WALK TESTER
1 Turning on the power selector switch after plugging
the cable into the Walk Tester Connector generates a
continuous beep at a constant sound level.
2 The beep sound becomes stronger and continues for a
longer period if an object is detected.
4-5
POWERING ON
Connect 24 VAC/DC to the power input terminal to
turn power on.
As power is turned on, the indicators (A1, A2, B1,
B2, Status and Power) light for about 30 seconds
and then go out.
During this period, REDSCAN initializes itself.
Indicator Power remains lit as long as power is
turned on.
Legend OFF Light Blink
4-6
SWITCH LAYOUT
4-7
LED FUNCTIONS
-In the normal operation
Symbol Color DETECTOR STATUS
A2 Red
Area A2 alarm output
A1
Red
Area A1 alarm output
B1
Red
Area B1 alarm output
B2 Red Area B2 alarm output
Status Yellow
Lit during auto setup of the unit.
(Turned off during normal operation.)
Power Green Lit when power is turned on
-When an abnormality occurs
Status
A2 A1 B1 B2
Status
Power
D.Q.
Anti-masking
Anti-rotation
Sensor
error
Error 1
Error 2
Error 3
Error 4
Error 5
Legend OFF Light Blink
5-1
SELECTOR SWITCH OPERATION
-Detection method selection
H1 Manual H1 Auto H2 Manual H2 Auto V Auto
Select the desired method using the detection
method selector switch.
Func.
H1
V
H2
SELECTOR
POSITION
FUNCTION
H1
It selects Horizontal Detection Area 1.
H2
It selects Horizontal Detection Area 2.
V
—
-Selection of the area setting method
H1 Manual H1 Auto H2 Manual H2 Auto V Auto
Select the desired method using the mode
selector switch.
Mode
M
A
SELECTOR
POSITION
FUNCTION
M
Selects the Manual setting.
A
Selects the Auto setting.
-Selecting the Auto mode
H1 Manual H1 Auto H2 Manual H2 Auto V Auto
Select it using the Auto mode selector switch.
Auto
P1
P2
SELECTOR
POSITION
FUNCTION
P1
Turns on the Auto Learning.
P2
Turns on the Auto Tracing.
Area A2 alarm output
Area A1 alarm output
Area B1 alarm output
Area B2 alarm output
Power selector
switch
Use at “REDWALL”
position.
WALK TESTER <OPM-WT>
REDSCAN
Approximately
30 seconds
(Initialization is
turned on)
Auto mode selection
Detection method selection
Detection area setting button
Operation Indicator
Tamper switch
Mode selection
Detection sensitivity setting (Size.)
Detection sensitivity setting (Sens.)
Offset adjustment
Area A ne alignment
potentiometer
Area B
ne alignment
potentiometer
Area A rough
alignment
Area B rough
alignment