Manual

- 8 -
- 9 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
Area B Area A
0
8
16
24
4
12
20
28
0
4
8
12
16
20
24
28
7
F
Fine
adj.
Area A
-1 +1 -1 +1
Area B
Range
0
8
16
24
4
12
20
28
0
4
8
12
16
20
24
28
7
F
Offset
-1 0
Set A2
Set A2
Power
A1
B1 B2
Status
REDWAVE
REDWAVE
MICROWAVE
REDWAVE
ALARM OUTPUT
CELL BATTERY
POWER
SUPPLY
FROM
SENSOR
POWER OFF
REDWAVE
PIR NEAR
REDWAVE
PIR FAR
MEGARED
FAR
MEGARED
NEAR
REDWALL
REDWIDE
WALKTESTER
REDWALL
REDWIDE
MEGARED
CONNECTION
SELECT
SWITCH
MODE
SELECT
SWITCH
POWER
SELECT
SWITCH
OPM-WT
1
2
Auto
P1
P2
-Selecting the detection sensitivity
H1 Manual H1 Auto H2 Manual H2 Auto V Auto
Set the detection sensitivity using the Size selector switch and
Sens. selector switch. You can set the detection sensitivity in the
horizontal area with the size of the target object and its move
distance within the detection area.
H
M
L
S
M
L
Size
Sens.
SELECTOR
POSITION
FUNCTION
S
Approx. 150 mm
(0.5 ft.) or above
This switch
species
the width of
the target
object to be
detected.
M
Approx. 300 mm
(1 ft.) or above
L
Approx. 1000 mm
(3.3 ft.) or above
H
Approx. 500 mm
(1.6 ft.) or above
This switch
species
the move
distance of an
object in the
detection area
above which
it is judged as
an intruder.
M
Approx. 1000 mm
(3.3 ft.) or above
L
Approx. 2000 mm
(6.6 ft.) or above
5-2
MANUAL SETTING OF HORIZONTAL DETECTION AREA
H1 Manual H1 Auto H2 Manual H2 Auto V Auto
Set a fan-like detection area using the rough alignment rotary
switch and fine alignment potentiometer.
-Rough alignment rotary switch
You can specify the radius in the range of 0 to 30 m in 2 m steps.
Setting the rough alignment rotary switch to 0 m deletes the area.
Example: if you specify “Detection distance in Area A: 30 m”
and “Detection distance in Area B: 14 m” in a location where the
radius is 30 m or more without a reflector, the following detection
areas will result.
SELECTOR
POSITION (m)
[ft.]
0 0
4 13
8 26
12
39
16
52
20 65
24 79
28 92
-Fine alignment potentiometer
This potentiometer can fine tune the value set with the rough
alignment rotary switch by +/- 1 m. within the range of 0 m
minimum and 30 m maximum.
Setting done in rough
alignment
Range available for fine alignment
When 0 m is set
0 to +1 m (From -1 to 0 m on the scale
is not usable)
When 2 to 28 m is set ±1 m
When 30
m is set
-
1 to 0 m (From 0 to +1 m on the scale
is not usable)
-Offset adjustment
You can reduce a set detection area using the offset
potentiometer. Use this adjusting function when windblown grass
or tree branches interfere with the currently set detection area.
You can adjust the boundary of a given detection area inward
(toward the sensor) in the range of 0 to -1 m.
5-3
STARTING SECURITY PROTECTION IN MANUAL MODE
H1 Manual H1 Auto H2 Manual H2 Auto V Auto
When “Manual” is chosen from the mode selector
switch, turning the power on starts the security
protection in manual mode.
5-4
AUTO SETTING OF HORIZONTAL DETECTION AREA
-Function of the detection area setting button
H1 Manual H1 Auto H2 Manual H2 Auto V Auto
This button starts the auto function of either P1 or
P2 whichever has been selected.
-Setting P1 (Auto Learning)
H1 Manual H1 Auto H2 Manual H2 Auto V Auto
Sequence of
operation
Status
indicator
Time
Action of REDSCAN/
Response of Walk Tester
1
Hold down the
detection area setting
button for 1 second.
Flashing
starts
For
1 second
Pitch of Walk Tester
sound changes for
2 seconds
2
Evacuation from
the area
Flashing (*1)
For
15 seconds
Fast flashing
(*2)
For
10 seconds
Scan of the detection
area is executed
ON
For
15 seconds
Scan of the detection
area is completed and
the data are saved
Flashing
For
3 seconds
OFF
Security protection of the
detection area is started
*1: Flashes once a second
*2: Flashes twice a second
Cautions >>
Do not enter the area while the area scan is being carried
out.
An unwanted object in the area interferes with the correct
scanning of the target area.
Offset
Offset
Auto P1 (Auto Learning)
Manual Mode
Area
B2
Area
B1
Area
A1
Area
A2
15 m
7 m
30 m14 m
: Detection area