Manual

- 10 -
- 11 -
SPECIFICATIONS
12
LED FUNCTIONS
Far areaFar area
Cautions>>
If the red LED keeps blinking for approx. 120 seconds
after turning the power on, turn the power off and then
on again.
DETECTOR STATUS If the cover is removed
During power ON Blinks.
During standby Turns OFF.
When detected (in far/near area) Lights.
11
10-2
If Tree Branches or Grass are Detected
When They Move Within the Detection Area
Points>>
Adjust the detection area so that it does not cover tree
branches or grass that move when the wind blows.
Check to see that the arrow of the main unit is within the
width of “Angle adjustment guide” on the adjustment screw.
Using the area viewfinder, check to see that the detection
area does not cover tree branches or grass that may move
when the wind blows.
Use the walk tester to listen for sound level changes when
there is no apparent activity in the detection area.
Adjust the detection area so that it does not detect
unwanted areas.
If the sound level changes, some part of the detection area
must be active (i.e.: an object is moving).
Use the walk tester and locate the part of the detection area
that is active. Change the walk tester selector switch
position and determine whether the active part of the
detection area is far or near.
Using the area viewfinder again, locate the active detection
area.
Mask the active detection area. To do this, mask the area
using the masking plate or the masking seal. Otherwise
mask the area using the far area masking switch (see Steps
5, 7, and 8).
Using the walk tester again, check that the sound level
changes. If the sound level does not change excessively,
you can finish the adjustment.
Points>>
You cannot mount and use both the area viewfinder and
the walk tester simultaneously.
(1)
(2)
(3)
(4)
(5)
(6)
(7)
12-1
Specications of the Main Unit
Applicable models
SIP-3020WF SIP-4010WF SIP-404WF
Model SIP-3020WF SIP-4010WF SIP-404WF
Detection method Passive infrared
Coverage
30 x 20m
(100 x 65ft.)
40 x 10m
(130 x 33ft.)
40 x 4m
(130 x 13ft.)
Number of detection
zones
74 zones 48 zones 24 zones
Mounting height 2.3 to 4m (7.6 to 13ft.)
Power input
3 - 9V DC
Alkaline or lithium battery
Operating voltage 2.5 - 10V DC
Current draw
40 µA (standby)
5mA max. (operating, LED ON)
Operation indicator RED ALARM
Warm-up period Approx. 120 sec.
Detection range
selector
Far area: ON / OFF
Alarm interval period
0 / 5 / 60 / 150 sec.
Detection logic
selector
AND/OR
Tamper output N.C. 10V DC, 0.01A max.
Trouble output N.C. 10V DC, 0.01A max.
Alarm output
N.C. 10V DC, 0.01A max.
N.O. 10V DC, 0.01A max.
Sensitivity selector Far: SH/H/M/L Near: SH/H/M/L
Operating temperature
-25 to +60°C (-13 to +140°F)
IP rating
Main unit: IP65
Chassis: IP55
Dimensions
(H × W × D)
227 x 102 x 266mm
(9 x 4 x 10.5 in.)
Weight 1.2kg (42 oz.)
Accessories
Screws, paper template, allen key, area
masking seal, tweezers, instruction
manual, area plate, fixing rubber form,
cable glands
Operation indicator - Red LED
REDWALL-V_SP-WF_EN.indd 10 2009/05/28 14:54:17